Left Atrial Appendage Electrical Isolation Reduces Residual Patency After Device Closure in Patients With Persistent Atrial Fibrillation

Background Left atrial appendage (LAA) patency after catheter ablation and LAA closure (LAAC) is a key determinant of postprocedure stroke. The effect of LAA electrical isolation (LAAEI) on LAA patency after LAAC in patients with atrial fibrillation (AF) remains unknown. Our objective was to explore the effect of LAAEI on LAA patency after catheter ablation and LAAC in patients with AF. Methods Patients with persistent AF who underwent combined catheter ablation and LAAC were enrolled. LAA patency was detected by cardiac computed tomographic angiography at 3 months after the procedure. Results A total of 686 patients with persistent AF with 3‐month device surveillance by cardiac computed tomographic angiography were included initially. Propensity score matching analysis was conducted on the basis of clinical features, echocardiographic parameters and procedural characteristics, and 469 patients were matched, including 363 with non‐LAAEI and 106 with LAAEI. Patients in matched groups showed 53.7% complete closure (no patency). Of the 46.3% of cases with LAA patency, visible peridevice leak was seen in 72.8%, and 27.2% had patency without visible peridevice leak. Compared with the non‐LAAEI group, the LAAEI group had a lower rate of LAA patency (49.6% versus 34.9%; adjusted odds ratio, 0.69 [95% CI, 0.48–0.98]; P =0.040). LAAEI was protective against LAA patency with an odds ratio of 0.68, and the other predictor of contrast leak into the LAA was maximum diameter of LAA orifice (odds ratio, 1.04 [95% CI, 1.00–1.08]; P =0.046). Conclusions LAAEI is an effective strategy for reducing LAA patency in patients with persistent AF undergoing combined catheter ablation and LAAC. Registration URL: clinicaltrials.gov ; Unique Identifier: NCT03788941.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-06-15
DOI
https://doi.org/10.1161/jaha.125.046374
Citations
1
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
11.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Left Atrial Appendage Electrical Isolation Reduces Residual Patency After Device Closure in Patients With Persistent Atrial Fibrillation

Peng‐Pai Zhang, R Zhang, Mu Chen, Xiao-Ming Lian et al.
1 citations
Journal of the American Heart Association
Atrial Fibrillation Management and Outcomes
11.19
article

Left Atrial Appendage Electrical Isolation Reduces Residual Patency After Device Closure in Patients With Persistent Atrial Fibrillation

Peng‐Pai Zhang, R Zhang, Mu Chen, Xiao-Ming Lian, Yi‐Gang Li, Q X Wang, Peng‐Cheng Yao, Qunshan Wang, Yudong Fei, Wei Li, Yang Xiao-min, Mei Yang, Jian Sun, Yan Zhao, Xingxing Cai, Zhi‐Xing Wei
article en
1 citations

Abstract

Background Left atrial appendage (LAA) patency after catheter ablation and LAA closure (LAAC) is a key determinant of postprocedure stroke. The effect of LAA electrical isolation (LAAEI) on LAA patency after LAAC in patients with atrial fibrillation (AF) remains unknown. Our objective was to explore the effect of LAAEI on LAA patency after catheter ablation and LAAC in patients with AF. Methods Patients with persistent AF who underwent combined catheter ablation and LAAC were enrolled. LAA patency was detected by cardiac computed tomographic angiography at 3 months after the procedure. Results A total of 686 patients with persistent AF with 3‐month device surveillance by cardiac computed tomographic angiography were included initially. Propensity score matching analysis was conducted on the basis of clinical features, echocardiographic parameters and procedural characteristics, and 469 patients were matched, including 363 with non‐LAAEI and 106 with LAAEI. Patients in matched groups showed 53.7% complete closure (no patency). Of the 46.3% of cases with LAA patency, visible peridevice leak was seen in 72.8%, and 27.2% had patency without visible peridevice leak. Compared with the non‐LAAEI group, the LAAEI group had a lower rate of LAA patency (49.6% versus 34.9%; adjusted odds ratio, 0.69 [95% CI, 0.48–0.98]; P =0.040). LAAEI was protective against LAA patency with an odds ratio of 0.68, and the other predictor of contrast leak into the LAA was maximum diameter of LAA orifice (odds ratio, 1.04 [95% CI, 1.00–1.08]; P =0.046). Conclusions LAAEI is an effective strategy for reducing LAA patency in patients with persistent AF undergoing combined catheter ablation and LAAC. Registration URL: clinicaltrials.gov ; Unique Identifier: NCT03788941.

Journal of the American Heart AssociationVol. 15(12)
Shanghai Jiao Tong University (CN)
Openalex Percentile: Top 1%
Atrial Fibrillation Management and Outcomes
11.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.