Optical origin of wide-field angular linearity in the human eye
When retinal position is expressed as an angle about the eye's second nodal point (α), this angle equals the field angle (θ) to within a degree up to far-peripheral eccentricities. Although this relation is used in various applications, its optical origin remained unknown. Here we explain this relation analytically and test its limits numerically. For a reduced eye model, we derive an exact relation between field angle and retinal angle and decompose the error (α-θ) into three terms: the angular demagnification by the cornea, the posterior offset of the nodal point from the pupil, and the curvature of the retina. The first two terms exactly cancel each other in the paraxial limit due to the eye's focus condition. At larger angles the third-order terms cancel when the nodal-point-to-retina distance is approximately 4/3 of the retinal radius, a condition that most eyes satisfy. Subsequent ray tracing of 4,000 statistically generated eyes confirms the mapping (mean absolute error 0.36 ± 0.27° at 40°) and identifies axial length and retinal radius as the main sources of residual error. It furthermore shows that the relation remains valid after cataract surgery with a recomputed nodal point.
Authors
- Jan‐Willem M. Beenakker (ORCID: https://orcid.org/0000-0003-0479-5587)
- Corné Haasjes (ORCID: https://orcid.org/0000-0003-0187-4116)
- Steven Habraken
Publication Details
- Published
- 2026-11-27
- DOI
- https://doi.org/10.1364/opticaopen.34971241
- Primary Topic
- Ophthalmology and Visual Impairment Studies
- Type
- preprint