Sparse-frequency EIS with SOC-conditioned fusion for lithium-ion battery SOH estimation: towards second-life screening

Rapid and non-destructive state-of-health (SOH) assessment is essential for second-life screening of lithium-ion batteries, whereas conventional capacity calibration is time-consuming and full-spectrum electrochemical impedance spectroscopy (EIS) requires measurements at many frequencies. This study proposes a sparse-frequency EIS framework with state-of-charge (SOC)-conditioned late fusion. A three-frequency configuration was selected from a fixed candidate library using physical-cell-level nested leave-one-cell-out (LOCO) validation, while EIS, equivalent-circuit-model (ECM)-style, and mechanism-inspired representations were integrated through SOC-conditioned fusion. The framework was evaluated using 72 EIS measurements from 24 laboratory-aged NMC811 cells in the public DIB_Data V3 dataset at 25 °C and 20%, 50%, and 70% SOC. Cross-cell selection concentrated mainly within 1–40 Hz; the most frequently selected candidate, 39.81, 25.12, and 1.585 Hz, was subsequently adopted as the fixed configuration for internal validation, corresponding to only 4.92% of the 61-point full spectrum. Nested LOCO yielded sample- and cell-level MAEs of 0.727 and 0.559 pp, respectively; the secondary fixed-C02 evaluation achieved a cell-level MAE of 0.532 ± 0.011 pp (mean ± SD across five ExtraTrees seeds). A separate outer-test-isolated comparison showed no observed deterioration relative to the 61-frequency baseline. SOC-conditioned fusion reduced cell-level MAE by 26.9% relative to equal-weight fusion without SOC, while 50% SOC emerged as a potential single-SOC condition in the post hoc analysis (MAE: 0.545 percentage points). A simplified timing model estimated a theoretical three-frequency impedance acquisition time of approximately 2.21 s after target-SOC stabilisation. At an illustrative 90% SOH threshold, sample-level classification accuracy was 97.22%, with 24/24 cells correctly classified at the cell level. These results support the engineering potential of fixed sparse-frequency EIS to balance SOH estimation accuracy and measurement complexity for second-life screening, while further source-independent and hardware-based validation remains necessary.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-27
DOI
https://doi.org/10.1088/2631-8695/aec79d
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sparse-frequency EIS with SOC-conditioned fusion for lithium-ion battery SOH estimation: towards second-life screening

Kai Zhu, Guobin Liang, Kailong Hu, Wei Lin
Engineering Research Express
Battery Modeling and Management
article

Sparse-frequency EIS with SOC-conditioned fusion for lithium-ion battery SOH estimation: towards second-life screening

Kai Zhu, Guobin Liang, Kailong Hu, Wei Lin
article en

Abstract

Rapid and non-destructive state-of-health (SOH) assessment is essential for second-life screening of lithium-ion batteries, whereas conventional capacity calibration is time-consuming and full-spectrum electrochemical impedance spectroscopy (EIS) requires measurements at many frequencies. This study proposes a sparse-frequency EIS framework with state-of-charge (SOC)-conditioned late fusion. A three-frequency configuration was selected from a fixed candidate library using physical-cell-level nested leave-one-cell-out (LOCO) validation, while EIS, equivalent-circuit-model (ECM)-style, and mechanism-inspired representations were integrated through SOC-conditioned fusion. The framework was evaluated using 72 EIS measurements from 24 laboratory-aged NMC811 cells in the public DIB_Data V3 dataset at 25 °C and 20%, 50%, and 70% SOC. Cross-cell selection concentrated mainly within 1–40 Hz; the most frequently selected candidate, 39.81, 25.12, and 1.585 Hz, was subsequently adopted as the fixed configuration for internal validation, corresponding to only 4.92% of the 61-point full spectrum. Nested LOCO yielded sample- and cell-level MAEs of 0.727 and 0.559 pp, respectively; the secondary fixed-C02 evaluation achieved a cell-level MAE of 0.532 ± 0.011 pp (mean ± SD across five ExtraTrees seeds). A separate outer-test-isolated comparison showed no observed deterioration relative to the 61-frequency baseline. SOC-conditioned fusion reduced cell-level MAE by 26.9% relative to equal-weight fusion without SOC, while 50% SOC emerged as a potential single-SOC condition in the post hoc analysis (MAE: 0.545 percentage points). A simplified timing model estimated a theoretical three-frequency impedance acquisition time of approximately 2.21 s after target-SOC stabilisation. At an illustrative 90% SOH threshold, sample-level classification accuracy was 97.22%, with 24/24 cells correctly classified at the cell level. These results support the engineering potential of fixed sparse-frequency EIS to balance SOH estimation accuracy and measurement complexity for second-life screening, while further source-independent and hardware-based validation remains necessary.

Engineering Research Express
Jiangsu University of Technology (CN)
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon