A Flexible Electrolyte-Side-Gated Organic Transistor for Noninvasive Salivary Glucose Sensing

Noninvasive monitoring of glucose in saliva offers a promising alternative to conventional blood-based measurements; however, the low physiological glucose concentration, matrix complexity, and interfacial instability of flexible sensors remain major challenges. Here, we report a flexible, low-voltage electrolyte side-gated organic transistor (ESGOT) on a polyimide substrate for salivary glucose detection. Interdigitated source–drain microelectrodes and a planar side gate were patterned by electroless copper deposition followed by galvanostatic silver electroplating (Cu/Ag). The channel is a solution-processed p-type Spiro-OMeTAD thin film doped with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) and 4-tert-butylpyridine (tBP), while the on-chip Ag quasi-reference electrode is functionalized with glucose oxidase (GOx) encapsulated in a permselective Nafion matrix. Operating at V DS = − 1.0 V and V GS = − 0.8 V, the device enables interfacial oxidation of enzymatically generated hydrogen peroxide at the functionalized side gate, which modulates the effective gate potential and changes the channel current. The sensor exhibited a measurable response over 0.1–1000 µM, with a validated quantitative range beginning at the LOQ of 2.70 µM and extending to 1000 µM through logarithmic calibration. The device exhibited a logarithmic sensitivity of 127.4 µA/decade (R² = 0.974), with an LOD of 0.81 µM and an LOQ of 2.70 µM.The devices showed a repeatability RSD of 2.67% and a fabrication reproducibility of 2.11% RSD. In a pilot comparison with capillary blood glucose in 20 participants, the sensor reached a correlation of r = 0.89. These results indicate the potential of the ESGOT platform for wearable point-of-care diagnostics.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-27
DOI
https://doi.org/10.21203/rs.3.rs-11752820/v1
Primary Topic
Electrochemical sensors and biosensors
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Flexible Electrolyte-Side-Gated Organic Transistor for Noninvasive Salivary Glucose Sensing

Zoheir Kordrostami, Mehdi Hosseini, Masoud Nasehi
Research Square
Electrochemical sensors and biosensors
preprint

A Flexible Electrolyte-Side-Gated Organic Transistor for Noninvasive Salivary Glucose Sensing

Zoheir Kordrostami, Mehdi Hosseini, Masoud Nasehi
preprint en

Abstract

Noninvasive monitoring of glucose in saliva offers a promising alternative to conventional blood-based measurements; however, the low physiological glucose concentration, matrix complexity, and interfacial instability of flexible sensors remain major challenges. Here, we report a flexible, low-voltage electrolyte side-gated organic transistor (ESGOT) on a polyimide substrate for salivary glucose detection. Interdigitated source–drain microelectrodes and a planar side gate were patterned by electroless copper deposition followed by galvanostatic silver electroplating (Cu/Ag). The channel is a solution-processed p-type Spiro-OMeTAD thin film doped with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) and 4-tert-butylpyridine (tBP), while the on-chip Ag quasi-reference electrode is functionalized with glucose oxidase (GOx) encapsulated in a permselective Nafion matrix. Operating at V DS = − 1.0 V and V GS = − 0.8 V, the device enables interfacial oxidation of enzymatically generated hydrogen peroxide at the functionalized side gate, which modulates the effective gate potential and changes the channel current. The sensor exhibited a measurable response over 0.1–1000 µM, with a validated quantitative range beginning at the LOQ of 2.70 µM and extending to 1000 µM through logarithmic calibration. The device exhibited a logarithmic sensitivity of 127.4 µA/decade (R² = 0.974), with an LOD of 0.81 µM and an LOQ of 2.70 µM.The devices showed a repeatability RSD of 2.67% and a fabrication reproducibility of 2.11% RSD. In a pilot comparison with capillary blood glucose in 20 participants, the sensor reached a correlation of r = 0.89. These results indicate the potential of the ESGOT platform for wearable point-of-care diagnostics.

Research Square
Shiraz University of Technology (IR)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon