Ethanol-based green RP-HPLC method for atogepant using analytical quality by design: validation and forced degradation profiling

Background Atogepant is a calcitonin gene-related peptide (CGRP) receptor antagonist that helps to prevent migraines. In this work, a green RP-HPLC method is developed using ethanol-water as the mobile phase, employing an AQbD approach. Methods Water content, flow rate, and column temperature were optimised using a 15-run Box-Behnken (BBD) experimental design. Conditions used were a C18 column (250 × 4.6 mm, 5 µm), ethanol-water (65:35, v/v), 0.8 mL/min, 35°C, and UV detection at 280 nm. Validation was per ICH Q2(R2). A blank injection demonstrated specificity, and forced degradation was performed under acidic, alkaline, oxidative, heat, and light conditions. Green analysis was performed with AGREE, GAPI, MoGAPI, ComplexGAPI, and HPLC-EAT. Results The ATO peak was at 4.8 min. Calibration was linear at 4–64 µg/mL (y = 18816x + 13413; R2 = 0.9998). LOD and LOQ were 1.006 and 3.047 µg/mL. Recovery was 98.00-100.13%. Intra- and inter-day %RSD were < 0.9%, robustness %RSD was < 2%. No peak was detected at the ATO retention time in the blank. Degradation led to a 10.32–16.92% loss of ATO. BBD predicted only the peak area; the selected conditions were at the boundary of the design space. AGREE, and MoGAPI scores were 0.58 and 63%, respectively. GAPI displayed seven green, five yellow, and three red fields. HPLC-EAT was 43% lower than the reference using acetonitrile. Conclusion Ethanol substitution improved greenness, but offline operation and waste volume are issues. Specificity was shown against a blank only; peak purity and resolution were not determined. Not a stability-indicating method; use in dosage form would require validation.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-27
DOI
https://doi.org/10.21203/rs.3.rs-11786156/v1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Ethanol-based green RP-HPLC method for atogepant using analytical quality by design: validation and forced degradation profiling

P Pattaluchetty, Ravandur Shivanna Chandan, Pavan Kumar M R, Manasa Chittipolu et al.
Research Square
Analytical Methods in Pharmaceuticals
preprint

Ethanol-based green RP-HPLC method for atogepant using analytical quality by design: validation and forced degradation profiling

P Pattaluchetty, Ravandur Shivanna Chandan, Pavan Kumar M R, Manasa Chittipolu, Prabhu Dev H, Rohit Chapiyavar
preprint en

Abstract

Background Atogepant is a calcitonin gene-related peptide (CGRP) receptor antagonist that helps to prevent migraines. In this work, a green RP-HPLC method is developed using ethanol-water as the mobile phase, employing an AQbD approach. Methods Water content, flow rate, and column temperature were optimised using a 15-run Box-Behnken (BBD) experimental design. Conditions used were a C18 column (250 × 4.6 mm, 5 µm), ethanol-water (65:35, v/v), 0.8 mL/min, 35°C, and UV detection at 280 nm. Validation was per ICH Q2(R2). A blank injection demonstrated specificity, and forced degradation was performed under acidic, alkaline, oxidative, heat, and light conditions. Green analysis was performed with AGREE, GAPI, MoGAPI, ComplexGAPI, and HPLC-EAT. Results The ATO peak was at 4.8 min. Calibration was linear at 4–64 µg/mL (y = 18816x + 13413; R2 = 0.9998). LOD and LOQ were 1.006 and 3.047 µg/mL. Recovery was 98.00-100.13%. Intra- and inter-day %RSD were < 0.9%, robustness %RSD was < 2%. No peak was detected at the ATO retention time in the blank. Degradation led to a 10.32–16.92% loss of ATO. BBD predicted only the peak area; the selected conditions were at the boundary of the design space. AGREE, and MoGAPI scores were 0.58 and 63%, respectively. GAPI displayed seven green, five yellow, and three red fields. HPLC-EAT was 43% lower than the reference using acetonitrile. Conclusion Ethanol substitution improved greenness, but offline operation and waste volume are issues. Specificity was shown against a blank only; peak purity and resolution were not determined. Not a stability-indicating method; use in dosage form would require validation.

Research Square
JSS Academy of Higher Education and Research (IN), JSS College of Pharmacy (IN)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon