AN EMPIRICAL EVALUATION OF INDOOR AND OUTDOOR LOCATION ACCURACY AND DIGITAL ADDRESSING LIMITATIONS IN GHANA: A CASE STUDY OF GHANAPOSTGPS
National digital addressing infrastructure underpins emergency medical dispatch, postal and courier logistics, fiscal revenue mobilisation, financial inclusion and civil registration across developing economies. In October 2017, the Republic of Ghana commissioned its official National Digital Property Addressing System (GhanaPostGPS), which partitions the country’s 238,535 km² landmass into over 9.5 billion nominal 5 m × 5 m (25 m²) grid cells identified by a hierarchical postal district code and unique locationcode. Despite mandatory administrative integration into national identification (Ghana Card), banking Know-Your-Customer (KYC) verification, tax registration and emergency services, operational discrepancies persist when citizens generate or resolve digital addresses indoors, within multi-household walled compounds, or inside multi-storey structures. Crucially, existing policy reviews frequently conflate continuous Global Navigation Satellite System (GNSS) coordinate accuracy with discrete grid-based digital address accuracy. This exploratory empirical casestudy mathematically and experimentally decouples continuous geodetic coordinate precision from discrete 5 m × 5 m digital address fidelity across tenpurposivelyselectedurban and peri-urban sites spanning five structural typologies (two sites per typology) in Accra, Tema, Madina and Kumasi. Using dual-frequency Real-Time Kinematic GNSS (RTK-GNSS) tied to the Ghana Lands Commission Continuously Operating Reference Stations (CORS) network and closed Total Station indoor traverses (with supporting geodetic verification records enumerated for audit archival), 40 ground-truth checkpoints (10 outdoor entrance/boundary benchmarks and 30 indoor checkpoints) were established. A hierarchically clustered sample of N = 480 repeated multi-platform observations (120 outdoor and 360 indoor measurements nested within 10 building clusters and 40 checkpoints) was recorded across three consumer smartphone tiers and four diurnal/meteorological sessions, benchmarking GhanaPostGPS against Google Fused Location Provider (Plus Codes) and standalone GNSS fixes. Withinthetenselectedsites,GhanaPostGPSrecorded a median outdoor horizontal coordinate error (CEP50) of 2.85 m (RMSE = 4.13 m; outdoor R95 = 7.86 m; 80.00% within 5.0 m), whereas indoor coordinate error degraded nearly fivefold to CEP50 = 14.08 m (indoor RMSE = 18.56 m; indoor-only R95 = 35.58 m; combined dataset RMSE = 16.21 m and combined overall R95 = 33.70 m; unclustered Mann-Whitney U = 41,286, p < 0.0001, subject to clustered confirmation), reaching CEP50 = 19.06 m in deep-core/UnitBcheckpoints and 21.65 m inthe two reinforced concrete high-risesites. Decoupled grid analysis reveals a pronounced Boundary Quantisation Paradox: although 80.00% of outdoor fixes fell within 5.0 m of ground truth, only 37.50% matched the exact target 5 m × 5 m code (A_grid; 55.94% Type-I boundary mismatch rate for e_H ≤ 5.0 m), whilst 75.83% lay within the target frontage/footprint polygon (A_poly). Indoors, exact 5 m × 5 m matching dropped to 5.00%, with provisionalthree-category compound tabulationsindicatingwidespread adjacent sub-building collision(23.61%)andexterior wall spill (48.89%),explicitlyflaggedhereinforobservation-levelreconciliation into a mutually exclusive four-category partition (including open-courtyard space) upon raw-dataset audit. BecauseGhanaPostGPSdeterministically encodes only 2D horizontal coordinates (I(Z; A_ref |E,N) = 0 bits), vertically stacked floorscarryzerosyntacticfloordifferentiationandyieldafinite uninformed floor-guessing probability of A_grid,indoor(z)/F. Five-predictor ordinary least squares (OLS) log-linear regression explains56.44% of log-error variance (F(5, 474) = 122.82, p < 0.0001), with carrier-to-noise density (C/N0, p = 0.0013), wall setback depth (p = 0.0026) and Sky View Factor (p = 0.0010) conditionallysignificantat the 1% level,HDOP (p = 0.0439) significant only at the 5% level and envelope attenuation (p = 0.1682)non-significant;anextendedmixed-effectsspecificationaccountingforbuilding/checkpointclustering,devicetier and epoch is formulated for raw-data re-estimation. Finally, this studyproposes a non-intrusive Dual-Stage Boundary-Gate Acquisition, Multi-Epoch Centroid Stabilisation and Hierarchical Sub-Unit Suffixing Protocol (DS-BGAS)thatavoids reliance on indoor GNSS for primary property-anchor addressing, accounts for temporal autocorrelation via effective samplesizeK_eff and applies ISO 19160-1 hierarchical suffixing (-Bxx-Fxx-Uxx) to enable unambiguous floor and room identification when accurately assigned and maintained. Provisional gate-anchored DS-BGAS findings (CEP50 = 0.64 m; RMSE = 0.80 m; 93.54% exact grid match/repeatability) are presented as promising preliminary evidence subject to independent verification of raw session logs, threshold pass/fail rates andtemporalautocorrelation prior to final certification.
Authors
- Richard Amponsah
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-27
- DOI
- https://doi.org/10.5281/zenodo.24583890
- Primary Topic
- GNSS positioning and interference
- Type
- article
- Field-Weighted Citation Impact
- 0.00