Position-dependent group factors for pile dragload due to negative skin friction: evaluation against published model tests

Estimating the dragload on individual piles in a group subjected to negative skin friction requires group-reduction factors that account for pile position, yet existing design formulations have rarely been benchmarked on a common experimental dataset. This study proposes a reproducible position-dependent extension of the analytical soil-column model (method L3) and evaluates it alongside the Chinese code JGJ 94-2008 (M1), the finite-element factors of Jeong et al. (1997) (M4) and the uniform soil-column solution (B0) against 88 group-to-single dragload ratios η = Fg/Fs compiled from 58 model-test series across five laboratories under pre-defined input rules. Analytical behaviour is governed by the surcharge ratio r = q/(γ′ln), comparing surface surcharge with effective soil weight above the neutral plane, and the hang-up number x = βπdln/As, comparing shaft friction capacity with the net interior column area As. Across the validation sources, JGJ 94-2008 strongly under-predicted η in high-surcharge test configurations (r > 5: source-weighted logarithmic RMSE of 1.72 versus 0.28 for r < 1) because its soil-weight limit omits the surcharge, whereas the fixed factors of Jeong et al. (1997) under-predicted interior piles (RMSE of 0.95), reflecting their derivation for long piles with large x. In the proposed L3 method, enlarging As by 1.5 for edge and 2.25 for corner piles and scaling by an empirical factor (κ = 1.11, calibrated to two centrifuge tests) reduced the validation RMSE from 0.28 (for B0) to 0.13, although it over-predicted one source at close spacing. However, combining group ratios with single-pile dragloads from the full-slip β method—which over-predicted two 1g sources 1.84-fold due to partial friction mobilisation—yielded large absolute dragload errors (RMSE of 0.52). The tests thus support L3 for relative group ratios within x ≤ 3.0 and groups up to 3×3, whereas prototype field tests are required to validate absolute dragload design.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-27
DOI
https://doi.org/10.1088/2631-8695/aec7a0
Primary Topic
Geotechnical Engineering and Soil Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Position-dependent group factors for pile dragload due to negative skin friction: evaluation against published model tests

Chen-xi Feng, Kun Chen
Engineering Research Express
Geotechnical Engineering and Soil Mechanics
article

Position-dependent group factors for pile dragload due to negative skin friction: evaluation against published model tests

Chen-xi Feng, Kun Chen
article en

Abstract

Estimating the dragload on individual piles in a group subjected to negative skin friction requires group-reduction factors that account for pile position, yet existing design formulations have rarely been benchmarked on a common experimental dataset. This study proposes a reproducible position-dependent extension of the analytical soil-column model (method L3) and evaluates it alongside the Chinese code JGJ 94-2008 (M1), the finite-element factors of Jeong et al. (1997) (M4) and the uniform soil-column solution (B0) against 88 group-to-single dragload ratios η = Fg/Fs compiled from 58 model-test series across five laboratories under pre-defined input rules. Analytical behaviour is governed by the surcharge ratio r = q/(γ′ln), comparing surface surcharge with effective soil weight above the neutral plane, and the hang-up number x = βπdln/As, comparing shaft friction capacity with the net interior column area As. Across the validation sources, JGJ 94-2008 strongly under-predicted η in high-surcharge test configurations (r > 5: source-weighted logarithmic RMSE of 1.72 versus 0.28 for r < 1) because its soil-weight limit omits the surcharge, whereas the fixed factors of Jeong et al. (1997) under-predicted interior piles (RMSE of 0.95), reflecting their derivation for long piles with large x. In the proposed L3 method, enlarging As by 1.5 for edge and 2.25 for corner piles and scaling by an empirical factor (κ = 1.11, calibrated to two centrifuge tests) reduced the validation RMSE from 0.28 (for B0) to 0.13, although it over-predicted one source at close spacing. However, combining group ratios with single-pile dragloads from the full-slip β method—which over-predicted two 1g sources 1.84-fold due to partial friction mobilisation—yielded large absolute dragload errors (RMSE of 0.52). The tests thus support L3 for relative group ratios within x ≤ 3.0 and groups up to 3×3, whereas prototype field tests are required to validate absolute dragload design.

Engineering Research Express
Nanyang Institute of Technology (CN)
Geotechnical Engineering and Soil Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon