Revisiting loss-on-ignition temperatures for organic matter determination: implications for organic matter removal efficiency in microplastics’ quantification

Digestion of organic matter (OM) in organic-rich solid matrices (ORSMs), such as landfill-mined soil-like fractions, landfill-mined residues, composts, and sediments, is an obligatory pre-treatment step in microplastics (MPs) quantification. In this regard, it is necessary to understand the optimal dosage of oxidizing agents for the digestion of OMs in the ORSMs. This optimal dosage is mainly based on Organic Matter Removal Efficiency (OMRE) of ORSMs, a widely adopted parameter in MP quantification studies. The OMRE is assessed through loss-on-ignition (LOI) of ORSMs at 550 °C, a commonly followed protocol, by comparing pre- and post-digestion mass losses. However, LOI at 550 °C overestimates the OM content in the ORSMs owing to the decomposition of clay minerals, viz., kaolinite, smectite. To address this anomaly/ambiguity, the present perspective study determined the OM using LOI at 440 °C (OM 440 °C) and LOI at 550 °C (OM 550 °C) for the above-mentioned ORSMs, quartz sand, kaolin, montmorillonite and bentonite. The findings show a consistent and systematic overestimation of OM at 550 °C, with deviations of approximately 8%–12% compared to OM 440 °C. It was realized that the overestimation of the OM at LOI 550 °C is predominantly due to the dihydroxylation of clay minerals and carbonate decomposition of inorganic mineral phases present in ORSMs. This perspective article establishes that the use of LOI 550 °C for the determination of OM consequently leads to its overestimation in ORSMs, thus contributing to the underestimation of OMRE. This anomaly introduces bias in establishing the appropriate dosage of the oxidizing agents and protocols for removing OM from ORSMs used in microplastic quantification. Furthermore, the present perspective article discusses the thermal processes governing the LOI measurements, at or above 550 °C, and its implications for OMRE and microplastics’ quantification.

Authors

Institutions

Publication Details

Journal
Frontiers in Environmental Chemistry
Published
2026-11-27
DOI
https://doi.org/10.3389/fenvc.2026.2039415
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Revisiting loss-on-ignition temperatures for organic matter determination: implications for organic matter removal efficiency in microplastics’ quantification

Venkata Siva Naga Sai Goli, Prithvendra Singh, Mrunal S. Bokade, Devendra Narain Singh
Frontiers in Environmental Chemistry
Microplastics and Plastic Pollution
article

Revisiting loss-on-ignition temperatures for organic matter determination: implications for organic matter removal efficiency in microplastics’ quantification

Venkata Siva Naga Sai Goli, Prithvendra Singh, Mrunal S. Bokade, Devendra Narain Singh
article en

Abstract

Digestion of organic matter (OM) in organic-rich solid matrices (ORSMs), such as landfill-mined soil-like fractions, landfill-mined residues, composts, and sediments, is an obligatory pre-treatment step in microplastics (MPs) quantification. In this regard, it is necessary to understand the optimal dosage of oxidizing agents for the digestion of OMs in the ORSMs. This optimal dosage is mainly based on Organic Matter Removal Efficiency (OMRE) of ORSMs, a widely adopted parameter in MP quantification studies. The OMRE is assessed through loss-on-ignition (LOI) of ORSMs at 550 °C, a commonly followed protocol, by comparing pre- and post-digestion mass losses. However, LOI at 550 °C overestimates the OM content in the ORSMs owing to the decomposition of clay minerals, viz., kaolinite, smectite. To address this anomaly/ambiguity, the present perspective study determined the OM using LOI at 440 °C (OM 440 °C) and LOI at 550 °C (OM 550 °C) for the above-mentioned ORSMs, quartz sand, kaolin, montmorillonite and bentonite. The findings show a consistent and systematic overestimation of OM at 550 °C, with deviations of approximately 8%–12% compared to OM 440 °C. It was realized that the overestimation of the OM at LOI 550 °C is predominantly due to the dihydroxylation of clay minerals and carbonate decomposition of inorganic mineral phases present in ORSMs. This perspective article establishes that the use of LOI 550 °C for the determination of OM consequently leads to its overestimation in ORSMs, thus contributing to the underestimation of OMRE. This anomaly introduces bias in establishing the appropriate dosage of the oxidizing agents and protocols for removing OM from ORSMs used in microplastic quantification. Furthermore, the present perspective article discusses the thermal processes governing the LOI measurements, at or above 550 °C, and its implications for OMRE and microplastics’ quantification.

Frontiers in Environmental ChemistryVol. 7
Indian Institute of Technology Bombay (IN), United Arab Emirates University (AE), Southeast University (CN)
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon