Dust Generation During Milling of Grey Cast Iron: Parametric Modeling of Particle Size Distribution

Particle size distribution (PSD) of dust generated during machining is a key parameter for designing dust control systems. In this study, 90 dust samples were collected from two milling machines under three milling modes, with and without air supply, at five points in the working area. The study is limited to grey cast iron grade SCH20 and to the investigated milling conditions. Sieve analysis was used, with laser diffraction (LALLS) validation for ten samples. The dust showed high polydispersity: the calculated number-based mean particle size ranged from 16.6 to 228 µm. In the investigated conditions, samples collected with air supply showed a smaller median particle size (70–120 μm vs. 50–70 μm); however, because different machines, tools and cutting parameters were used, this is interpreted as an observed effect rather than an isolated causal factor of air cooling. Comparison of the methods showed agreement in mass representation (5–7% discrepancy). However, in number-based representation, LALLS detected up to 35% of particles below the sieve analysis lower limit (26 μm). Calculated number-based PSDs were approximated using Weibull and lognormal distributions. The lognormal model provided slightly higher statistical accuracy (RMSE 2.4 vs. 2.9). Nevertheless, within the investigated conditions, the Weibull distribution is a provisional modeling option as a conservative engineering approximation for practical tasks. Its extrapolation below 26 μm predicts a higher proportion of fine fractions than the lognormal model; however, direct measurements of PM10, PM2.5 and PM1 were not performed, and these estimates are preliminary and require validation. Parameterized PSD models are presented for each milling mode and sampling point.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-27
DOI
https://doi.org/10.3390/app162311796
Primary Topic
Occupational Health and Safety in Workplaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dust Generation During Milling of Grey Cast Iron: Parametric Modeling of Particle Size Distribution

Yuriy Bulygin, Besarion Meskhi, Джедиров Дмитрий Александрович, Alexey S. Gumenyuk
Applied Sciences
Occupational Health and Safety in Workplaces
article

Dust Generation During Milling of Grey Cast Iron: Parametric Modeling of Particle Size Distribution

Yuriy Bulygin, Besarion Meskhi, Джедиров Дмитрий Александрович, Alexey S. Gumenyuk
article en

Abstract

Particle size distribution (PSD) of dust generated during machining is a key parameter for designing dust control systems. In this study, 90 dust samples were collected from two milling machines under three milling modes, with and without air supply, at five points in the working area. The study is limited to grey cast iron grade SCH20 and to the investigated milling conditions. Sieve analysis was used, with laser diffraction (LALLS) validation for ten samples. The dust showed high polydispersity: the calculated number-based mean particle size ranged from 16.6 to 228 µm. In the investigated conditions, samples collected with air supply showed a smaller median particle size (70–120 μm vs. 50–70 μm); however, because different machines, tools and cutting parameters were used, this is interpreted as an observed effect rather than an isolated causal factor of air cooling. Comparison of the methods showed agreement in mass representation (5–7% discrepancy). However, in number-based representation, LALLS detected up to 35% of particles below the sieve analysis lower limit (26 μm). Calculated number-based PSDs were approximated using Weibull and lognormal distributions. The lognormal model provided slightly higher statistical accuracy (RMSE 2.4 vs. 2.9). Nevertheless, within the investigated conditions, the Weibull distribution is a provisional modeling option as a conservative engineering approximation for practical tasks. Its extrapolation below 26 μm predicts a higher proportion of fine fractions than the lognormal model; however, direct measurements of PM10, PM2.5 and PM1 were not performed, and these estimates are preliminary and require validation. Parameterized PSD models are presented for each milling mode and sampling point.

Applied SciencesVol. 16(23)
Don State Technical University (RU)
Occupational Health and Safety in Workplaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.