Optical-lever-assisted microdeformation assessment using subpixel spot localization

A laboratory optical arrangement combines a rigid 146 deg dual-mirror target with two camera channels for subpixel laser-spot localization. A single incident beam illuminates the joined mirror region, and the two reflected paths are observed separately without a beam splitter or successive reflection of one ray by both mirrors. Spot intensity is fitted with a seven-parameter rotated elliptical Gaussian, followed by residual screening and channel-wise linear calibration. The dataset comprises 198 measurement images: three motion conditions, two camera channels, three repeats, and 11 settings per repeat. Camera 1’s best complete runs give mean absolute calibration deviations of 0.044 mm for pure translation, 0.020 deg for pure rotation, and 0.035 mm for displacement along a prescribed compound trajectory. Corresponding Camera 2 values are 0.060 mm, 0.025 deg, and 0.253 mm. Three-repeat means, sample standard deviations and standard errors are reported separately from the selected runs. Because calibration and evaluation use the same nominal setting labels, these results quantify in-sample calibration agreement rather than independent accuracy or total uncertainty. The compound analysis estimates displacement only; general independent translation–rotation separation is not established.

Authors

Institutions

Publication Details

Journal
Optical Engineering
Published
2026-11-27
DOI
https://doi.org/10.1117/1.oe.65.11.114107
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optical-lever-assisted microdeformation assessment using subpixel spot localization

Heng Wang, Qin Nie, Yuchen Wen, Ruochen Shi
Optical Engineering
Optical measurement and interference techniques
article

Optical-lever-assisted microdeformation assessment using subpixel spot localization

Heng Wang, Qin Nie, Yuchen Wen, Ruochen Shi
article en

Abstract

A laboratory optical arrangement combines a rigid 146 deg dual-mirror target with two camera channels for subpixel laser-spot localization. A single incident beam illuminates the joined mirror region, and the two reflected paths are observed separately without a beam splitter or successive reflection of one ray by both mirrors. Spot intensity is fitted with a seven-parameter rotated elliptical Gaussian, followed by residual screening and channel-wise linear calibration. The dataset comprises 198 measurement images: three motion conditions, two camera channels, three repeats, and 11 settings per repeat. Camera 1’s best complete runs give mean absolute calibration deviations of 0.044 mm for pure translation, 0.020 deg for pure rotation, and 0.035 mm for displacement along a prescribed compound trajectory. Corresponding Camera 2 values are 0.060 mm, 0.025 deg, and 0.253 mm. Three-repeat means, sample standard deviations and standard errors are reported separately from the selected runs. Because calibration and evaluation use the same nominal setting labels, these results quantify in-sample calibration agreement rather than independent accuracy or total uncertainty. The compound analysis estimates displacement only; general independent translation–rotation separation is not established.

Optical EngineeringVol. 65(11)
Shenyang Aerospace University (CN), Shenyang University of Technology (CN), Shenyang University (CN)
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon