Comparison of a novel portable wireless multichannel EEG with inbuilt seizure detection algorithm to a conventional EEG in a term neonatal cohort
Background Electroencephalography (EEG) has become increasingly important in neonatal neurocritical care. The use of continuous multichannel EEG (cEEG) can be limited in some settings by lack of expertise, personnel and resources. Alternatives to traditional cEEG devices need to be explored to allow more infants to avail of appropriate monitoring when indicated. The aim of this study was to assess the correlation of the signal recorded with a portable wireless EEG device with that of a conventional EEG monitor. Methods This was a single-centre, prospective method comparison study (NCT07508670). Near-term or term neonates requiring multichannel EEG were eligible for inclusion. EEG was simultaneously recorded on conventional (12 channel) and investigational (8-channel) devices using a single set of split electrodes. The primary outcome was EEG signal similarity between novel and conventional devices, assessed using Pearson correlation coefficients (PCCs). The secondary outcome was to describe the performance of the Neonatal Seizure Detection Algorithm (NSDA) compared to seizure annotation by an expert reviewer. Results 17 neonates, median gestation (interquartile range [IQR]) 39 + 2 weeks (38 + 4-40 + 6), were enrolled. A total of 342 h of overlapping EEG were analysed, median overlap in hours per recording was 19.48 (IQR: 14.91–21.70). The primary outcome analysis demonstrated that EEG signals were highly correlated between devices, median PCC=0.966 (95% confidence interval [CI]: 0.920 to 0.984). For the secondary outcome, while only one infant had seizures while connected to the investigational device, the NSDA identified all recorded seizures (n = 4), with 0.013 (95% CI 0.004–0.025) false detections per hour (FD/h). Conclusion The investigational device recorded EEG comparable to a conventional monitor. Its integrated NSDA identified all seizures in a single infant with infrequent false detections, but larger studies are required to test its clinical performance.
Authors
- Mark O’Sullivan (ORCID: https://orcid.org/0000-0001-9048-5459)
- Alison O'Shea (ORCID: https://orcid.org/0000-0002-8592-0599)
- Andreea M. Pavel (ORCID: https://orcid.org/0000-0002-7233-3408)
- Aisling Fanning
- Anne L. Murray (ORCID: https://orcid.org/0009-0008-3548-3969)
- Brian Henry Walsh (ORCID: https://orcid.org/0000-0003-4665-6884)
- Vicki Livingstone (ORCID: https://orcid.org/0000-0002-3309-1231)
- Sergio Morant Gálvez
Institutions
- University College Cork (IE)
- Cork University Hospital (IE)
- Infant (IE)
Publication Details
- Journal
- Frontiers in Pediatrics
- Published
- 2026-11-27
- DOI
- https://doi.org/10.3389/fped.2026.1892058
- Primary Topic
- EEG and Brain-Computer Interfaces
- Type
- article
- Field-Weighted Citation Impact
- 0.00