Comparison of a novel portable wireless multichannel EEG with inbuilt seizure detection algorithm to a conventional EEG in a term neonatal cohort

Background Electroencephalography (EEG) has become increasingly important in neonatal neurocritical care. The use of continuous multichannel EEG (cEEG) can be limited in some settings by lack of expertise, personnel and resources. Alternatives to traditional cEEG devices need to be explored to allow more infants to avail of appropriate monitoring when indicated. The aim of this study was to assess the correlation of the signal recorded with a portable wireless EEG device with that of a conventional EEG monitor. Methods This was a single-centre, prospective method comparison study (NCT07508670). Near-term or term neonates requiring multichannel EEG were eligible for inclusion. EEG was simultaneously recorded on conventional (12 channel) and investigational (8-channel) devices using a single set of split electrodes. The primary outcome was EEG signal similarity between novel and conventional devices, assessed using Pearson correlation coefficients (PCCs). The secondary outcome was to describe the performance of the Neonatal Seizure Detection Algorithm (NSDA) compared to seizure annotation by an expert reviewer. Results 17 neonates, median gestation (interquartile range [IQR]) 39 + 2 weeks (38 + 4-40 + 6), were enrolled. A total of 342 h of overlapping EEG were analysed, median overlap in hours per recording was 19.48 (IQR: 14.91–21.70). The primary outcome analysis demonstrated that EEG signals were highly correlated between devices, median PCC=0.966 (95% confidence interval [CI]: 0.920 to 0.984). For the secondary outcome, while only one infant had seizures while connected to the investigational device, the NSDA identified all recorded seizures (n = 4), with 0.013 (95% CI 0.004–0.025) false detections per hour (FD/h). Conclusion The investigational device recorded EEG comparable to a conventional monitor. Its integrated NSDA identified all seizures in a single infant with infrequent false detections, but larger studies are required to test its clinical performance.

Authors

Institutions

Publication Details

Journal
Frontiers in Pediatrics
Published
2026-11-27
DOI
https://doi.org/10.3389/fped.2026.1892058
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of a novel portable wireless multichannel EEG with inbuilt seizure detection algorithm to a conventional EEG in a term neonatal cohort

Mark O’Sullivan, Alison O'Shea, Andreea M. Pavel, Aisling Fanning et al.
Frontiers in Pediatrics
EEG and Brain-Computer Interfaces
article

Comparison of a novel portable wireless multichannel EEG with inbuilt seizure detection algorithm to a conventional EEG in a term neonatal cohort

Mark O’Sullivan, Alison O'Shea, Andreea M. Pavel, Aisling Fanning, Anne L. Murray, Brian Henry Walsh, Vicki Livingstone, Sergio Morant Gálvez
article en

Abstract

Background Electroencephalography (EEG) has become increasingly important in neonatal neurocritical care. The use of continuous multichannel EEG (cEEG) can be limited in some settings by lack of expertise, personnel and resources. Alternatives to traditional cEEG devices need to be explored to allow more infants to avail of appropriate monitoring when indicated. The aim of this study was to assess the correlation of the signal recorded with a portable wireless EEG device with that of a conventional EEG monitor. Methods This was a single-centre, prospective method comparison study (NCT07508670). Near-term or term neonates requiring multichannel EEG were eligible for inclusion. EEG was simultaneously recorded on conventional (12 channel) and investigational (8-channel) devices using a single set of split electrodes. The primary outcome was EEG signal similarity between novel and conventional devices, assessed using Pearson correlation coefficients (PCCs). The secondary outcome was to describe the performance of the Neonatal Seizure Detection Algorithm (NSDA) compared to seizure annotation by an expert reviewer. Results 17 neonates, median gestation (interquartile range [IQR]) 39 + 2 weeks (38 + 4-40 + 6), were enrolled. A total of 342 h of overlapping EEG were analysed, median overlap in hours per recording was 19.48 (IQR: 14.91–21.70). The primary outcome analysis demonstrated that EEG signals were highly correlated between devices, median PCC=0.966 (95% confidence interval [CI]: 0.920 to 0.984). For the secondary outcome, while only one infant had seizures while connected to the investigational device, the NSDA identified all recorded seizures (n = 4), with 0.013 (95% CI 0.004–0.025) false detections per hour (FD/h). Conclusion The investigational device recorded EEG comparable to a conventional monitor. Its integrated NSDA identified all seizures in a single infant with infrequent false detections, but larger studies are required to test its clinical performance.

Frontiers in PediatricsVol. 14
University College Cork (IE), Cork University Hospital (IE), Infant (IE)
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon