A Low-Cost Dual-Site Photoplethysmography Platform for Millisecond-Resolution Pulse Arrival Time Difference: Design, Timing-Error Analysis, and Validation Protocol

This research presents the design and timing-error analysis of a low-cost dual-site photoplethysmography (PPG) platform for measuring millisecond-resolution pulse arrival time differences. The system integrates two MAX30102 optical sensors, an ESP32-C3 microcontroller, and a TCA9548A I2C multiplexer to acquire synchronized pulse signals from two measurement sites. It employs hardware interrupt-based timestamping and an advanced pulse-foot detection algorithm to improve timing accuracy. Monte Carlo simulations investigate the effects of sampling frequency, signal noise, and detection methods on measurement error. Additionally, a three-experiment validation protocol evaluates signal quality, timing accuracy, and physiological plausibility. The platform aims to provide an affordable research tool for investigating peripheral vascular characteristics without making clinical diagnostic claims.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-27
DOI
https://doi.org/10.5281/zenodo.24595148
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Low-Cost Dual-Site Photoplethysmography Platform for Millisecond-Resolution Pulse Arrival Time Difference: Design, Timing-Error Analysis, and Validation Protocol

Moaaz Ahmed Abdlhamed Mohammed Salem
Zenodo (CERN European Organization for Nuclear Research)
Non-Invasive Vital Sign Monitoring
preprint

A Low-Cost Dual-Site Photoplethysmography Platform for Millisecond-Resolution Pulse Arrival Time Difference: Design, Timing-Error Analysis, and Validation Protocol

Moaaz Ahmed Abdlhamed Mohammed Salem
preprint en

Abstract

This research presents the design and timing-error analysis of a low-cost dual-site photoplethysmography (PPG) platform for measuring millisecond-resolution pulse arrival time differences. The system integrates two MAX30102 optical sensors, an ESP32-C3 microcontroller, and a TCA9548A I2C multiplexer to acquire synchronized pulse signals from two measurement sites. It employs hardware interrupt-based timestamping and an advanced pulse-foot detection algorithm to improve timing accuracy. Monte Carlo simulations investigate the effects of sampling frequency, signal noise, and detection methods on measurement error. Additionally, a three-experiment validation protocol evaluates signal quality, timing accuracy, and physiological plausibility. The platform aims to provide an affordable research tool for investigating peripheral vascular characteristics without making clinical diagnostic claims.

Zenodo (CERN European Organization for Nuclear Research)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon