An integrated field workflow (drone–GIS–IoT–LoRaWAN) for generating indoor thermal exposure data in Sahelian households (Matam region, Senegal)

In Sahelian regions, assessments of population exposure to heat rely mainly on weather-station measurements or climate reanalysis datasets. Indoor thermal conditions are rarely measured in these settings, although they contribute to population heat exposure. We describe and evaluate a unique field workflow that produces hourly indoor temperature and humidity series in households at four urban and rural sites in the Matam region, north-eastern Senegal. The workflow has seven steps: acquisition of thermal drone imagery, or very-high-resolution satellite imagery where drone flights were prohibited; manual digitisation of roofs and classification of roof type and apparent thermal response in a geographic information system; stratified random spatial sampling of dwellings; field validation with an acceptability survey; installation of low-cost indoor sensors and local weather stations; long-range low-power radio transmission; and data hosting in a database with a dashboard. A total of 1,073 indoor sensors were installed. Over the monitoring period (1 May 2025 to 30 April 2026), 65.0% of the expected hourly observations were received. Almost all missing observations (99.6%) resulted from transmission interruptions or sensor attrition rather than invalid values, and 30.0% of sensors stopped transmitting before the end of the period. Gaps of up to 168 hours were reconstructed with a mean absolute error between 0.12 and 0.30 °C on a held-out test set. The workflow produces spatially referenced indoor temperature time series that can be linked to dwelling characteristics and local outdoor conditions in an isolated, sparsely mapped setting. It could be adapted to document exposure to extreme heat in other poorly instrumented settings.

Authors

Institutions

Publication Details

Journal
EarthArXiv (California Digital Library)
Published
2026-11-27
DOI
https://doi.org/10.31223/x5p23f
Primary Topic
Urban Heat Island Mitigation
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

An integrated field workflow (drone–GIS–IoT–LoRaWAN) for generating indoor thermal exposure data in Sahelian households (Matam region, Senegal)

Pauline Gluski, Yann Lefebvre, Emmanuel Bonnet, Labaly Touré et al.
EarthArXiv (California Digital Library)
Urban Heat Island Mitigation
preprint

An integrated field workflow (drone–GIS–IoT–LoRaWAN) for generating indoor thermal exposure data in Sahelian households (Matam region, Senegal)

Pauline Gluski, Yann Lefebvre, Emmanuel Bonnet, Labaly Touré, Sari R. Kovats, Valéry Ridde, Jean-Marc Goudet, Véronique Filippi, Fatimata Sow, Mouhamadou zaidou, Adama Faye
preprint en

Abstract

In Sahelian regions, assessments of population exposure to heat rely mainly on weather-station measurements or climate reanalysis datasets. Indoor thermal conditions are rarely measured in these settings, although they contribute to population heat exposure. We describe and evaluate a unique field workflow that produces hourly indoor temperature and humidity series in households at four urban and rural sites in the Matam region, north-eastern Senegal. The workflow has seven steps: acquisition of thermal drone imagery, or very-high-resolution satellite imagery where drone flights were prohibited; manual digitisation of roofs and classification of roof type and apparent thermal response in a geographic information system; stratified random spatial sampling of dwellings; field validation with an acceptability survey; installation of low-cost indoor sensors and local weather stations; long-range low-power radio transmission; and data hosting in a database with a dashboard. A total of 1,073 indoor sensors were installed. Over the monitoring period (1 May 2025 to 30 April 2026), 65.0% of the expected hourly observations were received. Almost all missing observations (99.6%) resulted from transmission interruptions or sensor attrition rather than invalid values, and 30.0% of sensors stopped transmitting before the end of the period. Gaps of up to 168 hours were reconstructed with a mean absolute error between 0.12 and 0.30 °C on a held-out test set. The workflow produces spatially referenced indoor temperature time series that can be linked to dwelling characteristics and local outdoor conditions in an isolated, sparsely mapped setting. It could be adapted to document exposure to extreme heat in other poorly instrumented settings.

EarthArXiv (California Digital Library)
Centre National de la Recherche Scientifique (FR), Inserm (FR), Université Paris Cité (FR), Pôle de Recherche pour l'Organisation et la Diffusion de l'Information Géographique (FR), London School of Hygiene & Tropical Medicine (GB), Université Sorbonne Paris Nord (FR), Centre Population et Développement (FR), Institut de Recherche pour le Développement (FR), Université Paris 1 Panthéon-Sorbonne (FR), Cheikh Anta Diop University (SN)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.