Heat Indices of Selected Buildings at the University of Northern Philippines
The heat indices of rooms without air conditioner of three selected buildings at the University of Northern Philippines were analyzed. We measure the temperature and relative humidity in the dif- ferent buildings using the INGCO HETHT01 digital humidity and temperature meter from November 2023 to December 2023, at different times of the day, from 8:00 to 9:00, 12:00 to 13:00 and 16:00 to 17:00. We use Lans P. Rothfusz’s heat index equation to calculate the heat indices of each build- ing. The heat indices of the buildings are higher than the tolerable heat index, where the College of Architecture Building recorded the highest. We find that the heat index being reported in media is different than the heat indices in these buildings. It might be prudent that heat indices inside the classroom be calculated than rely on heat indices quoted in the internet or media as these are based on measurements outside of the actual classroom. Our results can be used for policy making and class scheduling.
Authors
- Lesley Joy T. Baldonado
Publication Details
- Journal
- International Journal of Innovative Science and Research Technology (IJISRT)
- Published
- 2026-11-27
- DOI
- https://doi.org/10.38124/ijisrt/26nov1106
- Primary Topic
- Building Energy and Comfort Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00