Tendon Reconstruction in the Red‐Red Zone at 10 mm Provides Favorable Biomechanical Stability for Medial Meniscus Posterior Root Tears: A Porcine Biomechanical Study

PURPOSE: To determine the optimal reconstruction zone and distance for tendon reconstruction of medial meniscus posterior root tears based on biomechanical performance. METHODS: Thirty-six porcine knees with standardized medial meniscus posterior root tears underwent tendon reconstruction and were allocated to reconstruction in the red-red zone (Group A) or red-white zone (Group B). Each group was subdivided by reconstruction distance (5, 10, and 15 mm; n = 6 each). Constructs underwent cyclic loading (10-30 N, 1000 cycles), followed by load-to-failure testing. Cyclic displacement, ultimate failure load, elongation, stiffness, and failure modes were recorded. RESULTS: Group A revealed smaller cyclic displacement than Group B after 1000 cycles (2.81 ± 0.16 vs 3.21 ± 0.13 mm; P < .001) and a higher ultimate failure load (291.04 ± 90.59 vs 196.88 ± 41.47 N; P < .001), whereas no between-group differences were observed in elongation (P = .975) or stiffness (P = .429). Regarding reconstruction distance, ultimate failure load in Group A was lower at 5 mm than at 10 and 15 mm (190.48 ± 51.51 N vs 344.90 ± 68.89 N and 337.73 ± 47.45 N, respectively; P < .001), whereas no significant differences were observed among distance subgroups in Group B (P = .390). In both groups, elongation was greater, and stiffness was lower at 5 mm than at 10 and 15 mm (all P < .028). A significant zone-distance interaction was observed for failure load (P < .001). All specimens failed by tendon cut-through. CONCLUSIONS: Reconstruction in the red-red zone provides greater biomechanical stability than reconstruction in the red-white zone, and a 10-mm reconstruction distance offers greater strength than 5 mm with no additional biomechanical benefit at 15 mm. CLINICAL RELEVANCE: These findings provide biomechanical guidance for optimizing tendon reconstruction strategies for medial meniscus posterior root tears.

Authors

Institutions

Publication Details

Journal
Arthroscopy The Journal of Arthroscopic and Related Surgery
Published
2026-11-27
DOI
https://doi.org/10.1002/arj.70757
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Tendon Reconstruction in the Red‐Red Zone at 10 mm Provides Favorable Biomechanical Stability for Medial Meniscus Posterior Root Tears: A Porcine Biomechanical Study

Daijun Xie, Zhongcheng Liu, Jin Jiang, Yian Sun et al.
Arthroscopy The Journal of Arthroscopic and Related Surgery
Knee injuries and reconstruction techniques
article

Tendon Reconstruction in the Red‐Red Zone at 10 mm Provides Favorable Biomechanical Stability for Medial Meniscus Posterior Root Tears: A Porcine Biomechanical Study

Daijun Xie, Zhongcheng Liu, Jin Jiang, Yian Sun, Jilei Wang, Xu Li, Meng Wu
article en

Abstract

PURPOSE: To determine the optimal reconstruction zone and distance for tendon reconstruction of medial meniscus posterior root tears based on biomechanical performance. METHODS: Thirty-six porcine knees with standardized medial meniscus posterior root tears underwent tendon reconstruction and were allocated to reconstruction in the red-red zone (Group A) or red-white zone (Group B). Each group was subdivided by reconstruction distance (5, 10, and 15 mm; n = 6 each). Constructs underwent cyclic loading (10-30 N, 1000 cycles), followed by load-to-failure testing. Cyclic displacement, ultimate failure load, elongation, stiffness, and failure modes were recorded. RESULTS: Group A revealed smaller cyclic displacement than Group B after 1000 cycles (2.81 ± 0.16 vs 3.21 ± 0.13 mm; P < .001) and a higher ultimate failure load (291.04 ± 90.59 vs 196.88 ± 41.47 N; P < .001), whereas no between-group differences were observed in elongation (P = .975) or stiffness (P = .429). Regarding reconstruction distance, ultimate failure load in Group A was lower at 5 mm than at 10 and 15 mm (190.48 ± 51.51 N vs 344.90 ± 68.89 N and 337.73 ± 47.45 N, respectively; P < .001), whereas no significant differences were observed among distance subgroups in Group B (P = .390). In both groups, elongation was greater, and stiffness was lower at 5 mm than at 10 and 15 mm (all P < .028). A significant zone-distance interaction was observed for failure load (P < .001). All specimens failed by tendon cut-through. CONCLUSIONS: Reconstruction in the red-red zone provides greater biomechanical stability than reconstruction in the red-white zone, and a 10-mm reconstruction distance offers greater strength than 5 mm with no additional biomechanical benefit at 15 mm. CLINICAL RELEVANCE: These findings provide biomechanical guidance for optimizing tendon reconstruction strategies for medial meniscus posterior root tears.

Arthroscopy The Journal of Arthroscopic and Related Surgery
Lanzhou University Second Hospital (CN)
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon