Reference Values for Electrocardiographic Parameters With Guideline‐Recommended Filter Settings in the School‐Age Population and Comparison With a Previous Study Using Lower Low‐Pass Cutoff Settings

Background Reference values of electrocardiographic (ECG) findings with guideline‐recommended filters (hereafter, without filters) from a large number of pediatric subjects are lacking in Japan. The effects of lower low‐pass cutoff filters (with filters) on QRS amplitudes have not been well clarified. Methods A total of 60 406 pediatric participants' ECGs without filters at school‐based screening programs were obtained between 2016 and 2021. Each ECG was manually checked by 2 pediatric cardiologists, and only ECGs with sinus rhythm were included. Baseline drift, artifacts, and noise that could affect the automatic measurement of PQRS amplitudes and durations were observed in 24 588 ECGs and thoroughly excluded. Finally, 30 256 ECGs of 7372 first graders (boys/girls = 3784/3588), 8910 seventh graders (4300/4610), and 13 974 10th graders (6852/7122) were analyzed. ECG parameters without filters were determined and compared with those of previous data with filters. Results ECG parameters without filters were newly established. The difference in QRS amplitudes between the present and previous data followed the order of Q > S > R waves, right > mid‐ > left precordial leads for R waves, and left > mid‐ > right precordial leads for S waves. The difference in amplitude was more marked in girls than in boys. The prevalence of J wave also differed substantially between the two studies. Conclusions This study established the reference values for ECG parameters without filters. The differences between the two studies may have been influenced not only by filter settings but also by differences in study populations and recording conditions.

Authors

Institutions

Publication Details

Journal
Journal of Arrhythmia
Published
2026-11-27
DOI
https://doi.org/10.1002/joa3.70522
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reference Values for Electrocardiographic Parameters With Guideline‐Recommended Filter Settings in the School‐Age Population and Comparison With a Previous Study Using Lower Low‐Pass Cutoff Settings

Takashi Higaki, Tatsunori Hokosaki, Nobuo Tauchi, Hiroya Ushinohama et al.
Journal of Arrhythmia
ECG Monitoring and Analysis
article

Reference Values for Electrocardiographic Parameters With Guideline‐Recommended Filter Settings in the School‐Age Population and Comparison With a Previous Study Using Lower Low‐Pass Cutoff Settings

Takashi Higaki, Tatsunori Hokosaki, Nobuo Tauchi, Hiroya Ushinohama, Masao Yoshinaga, Naomi Izumida, Hitoshi Horigome, Mamoru Ayusawa, Mari Iwamoto, Toshiyuki Chisaka, Naokata Sumitomo, Tatsuya Yoneyama, Taichi Kato, Yoshiaki Kato, Hideto Takahashi, Masami Nagashima, Hiromitsu Ogata, Katsumi Abe
article en

Abstract

Background Reference values of electrocardiographic (ECG) findings with guideline‐recommended filters (hereafter, without filters) from a large number of pediatric subjects are lacking in Japan. The effects of lower low‐pass cutoff filters (with filters) on QRS amplitudes have not been well clarified. Methods A total of 60 406 pediatric participants' ECGs without filters at school‐based screening programs were obtained between 2016 and 2021. Each ECG was manually checked by 2 pediatric cardiologists, and only ECGs with sinus rhythm were included. Baseline drift, artifacts, and noise that could affect the automatic measurement of PQRS amplitudes and durations were observed in 24 588 ECGs and thoroughly excluded. Finally, 30 256 ECGs of 7372 first graders (boys/girls = 3784/3588), 8910 seventh graders (4300/4610), and 13 974 10th graders (6852/7122) were analyzed. ECG parameters without filters were determined and compared with those of previous data with filters. Results ECG parameters without filters were newly established. The difference in QRS amplitudes between the present and previous data followed the order of Q > S > R waves, right > mid‐ > left precordial leads for R waves, and left > mid‐ > right precordial leads for S waves. The difference in amplitude was more marked in girls than in boys. The prevalence of J wave also differed substantially between the two studies. Conclusions This study established the reference values for ECG parameters without filters. The differences between the two studies may have been influenced not only by filter settings but also by differences in study populations and recording conditions.

Journal of ArrhythmiaVol. 42(6)
Fukushima Medical University (JP), Kanagawa Institute of Technology (JP), Kagawa Nutrition University (JP), Fukuoka Children's Hospital and Medical Center for Infectious Diseases (JP), National Cerebral and Cardiovascular Center (JP), Saitama International Medical Center (JP), Fukuda Denshi (Japan) (JP), Kagoshima Medical Center (JP), Ehime University (JP), Tokyo Health Service Association (JP), National Hospital Organization Yokohama Medical Center (JP), Nagoya University (JP), Saitama Medical University (JP)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon