High-sensitivity metal–insulator–metal waveguide sensor with independently tunable triple Fano resonances for glucose and hemoglobin concentration sensing
A high-sensitivity metal–insulator–metal (MIM) waveguide sensor with independently tunable triple Fano resonances is proposed for glucose and hemoglobin concentration sensing. The structure consists of an MIM bus waveguide side-coupled to two asymmetric T-shaped cavities, where the interference between discrete cavity modes and the continuum produces three sharp Fano resonances. Finite-difference time-domain simulations show that the three resonance modes can be selectively tuned by adjusting the cavity geometry. After optimization, the sensor achieves a maximum refractive index sensitivity (S) of 2228.55 nm/RIU and a figure of merit of 5110.69. By loading glucose and hemoglobin solutions into different cavities, dual-analyte concentration sensing is realized, with sensitivities of 0.2535 and 0.2499 nm g/L, respectively. The proposed structure provides a compact and promising platform for integrated biochemical sensing.
Authors
- Jiao Fu (ORCID: https://orcid.org/0000-0003-4402-8809)
- Qin Lu (ORCID: https://orcid.org/0009-0007-8211-0068)
- Hao Liu (ORCID: https://orcid.org/0000-0003-0089-4254)
- Haopeng Hou
- Yankun Wu
- Zihe Shang Guan (ORCID: https://orcid.org/0009-0005-3894-3404)
- Yifan Jia
- Xuhang Chen
Institutions
- Xi’an University of Posts and Telecommunications (CN)
Publication Details
- Journal
- Optical Engineering
- Published
- 2026-11-27
- DOI
- https://doi.org/10.1117/1.oe.65.11.117108
- Primary Topic
- Plasmonic and Surface Plasmon Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00