Simple and selective isocratic RP-HPLC method for determination of lufenuron in technical material and emulsifiable concentrate formulated products

Lufenuron is an active insecticide agent widely applied for protecting plants from pests. This analytical research aims to establish and validate the RP-HPLC (Reverse Phase High Performance Liquid Chromatography) method for estimation of lufenuron concentration in its technical grade form and in an emulsifiable concentrate (EC) insecticide formulation. The Brownlee™ C-18 column (5 μm, 250 × 4.6 mm) utilizes a stationary phase, with a mobile phase consisting of methanol and distilled water in a 90:10% v/v ratio. The flow rate was sustained at 1.2 mL/min, with detection occurring at 254 nm. The validation study followed SANCO/3030/99 rev.5 and ICH Q2(R2) which include calculating the parameters of selectivity, specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), robustness, precision, recovery, and accuracy. The retention time of Lufenuron was determined to be about 3.32 min. The proposed method showed good linearity over the working assay range of 100–600 µg/mL, with a Pearson correlation coefficient (r) of 0.9975 and a coefficient of determination (R²) of 0.995. The method demonstrated satisfactory precision, with RSD values of 0.27–0.47%, the elevated recovery values of 100.02%-100.43% signify a satisfactory accuracy. Additionally, the greenness profile of the proposed method was evaluated using the AGREE metric, yielding an overall score of 0.55. Unlike previously reported HPLC methods that mainly focused on trace-level residue determination in food and environmental matrices and often involved gradient elution or more complex sample preparation, the proposed method was specifically developed for routine quality-control assay of lufenuron in technical material and emulsifiable concentrate formulations owing to its simplicity, short run time, and reliable performance.

Authors

Institutions

Publication Details

Journal
Discover Chemistry.
Published
2026-11-27
DOI
https://doi.org/10.1007/s44371-026-01129-y
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Simple and selective isocratic RP-HPLC method for determination of lufenuron in technical material and emulsifiable concentrate formulated products

Ismael M. Elkamhawy
Discover Chemistry.
Pesticide Residue Analysis and Safety
article

Simple and selective isocratic RP-HPLC method for determination of lufenuron in technical material and emulsifiable concentrate formulated products

Ismael M. Elkamhawy
article en

Abstract

Lufenuron is an active insecticide agent widely applied for protecting plants from pests. This analytical research aims to establish and validate the RP-HPLC (Reverse Phase High Performance Liquid Chromatography) method for estimation of lufenuron concentration in its technical grade form and in an emulsifiable concentrate (EC) insecticide formulation. The Brownlee™ C-18 column (5 μm, 250 × 4.6 mm) utilizes a stationary phase, with a mobile phase consisting of methanol and distilled water in a 90:10% v/v ratio. The flow rate was sustained at 1.2 mL/min, with detection occurring at 254 nm. The validation study followed SANCO/3030/99 rev.5 and ICH Q2(R2) which include calculating the parameters of selectivity, specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), robustness, precision, recovery, and accuracy. The retention time of Lufenuron was determined to be about 3.32 min. The proposed method showed good linearity over the working assay range of 100–600 µg/mL, with a Pearson correlation coefficient (r) of 0.9975 and a coefficient of determination (R²) of 0.995. The method demonstrated satisfactory precision, with RSD values of 0.27–0.47%, the elevated recovery values of 100.02%-100.43% signify a satisfactory accuracy. Additionally, the greenness profile of the proposed method was evaluated using the AGREE metric, yielding an overall score of 0.55. Unlike previously reported HPLC methods that mainly focused on trace-level residue determination in food and environmental matrices and often involved gradient elution or more complex sample preparation, the proposed method was specifically developed for routine quality-control assay of lufenuron in technical material and emulsifiable concentrate formulations owing to its simplicity, short run time, and reliable performance.

Discover Chemistry.Vol. 3(1)
Damanhour University (EG)
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon