Waste Heat Recovery Limits for Energy-Efficient Climate Control in Mobile Working Machines

Low-grade waste heat may potentially support desiccant regeneration in the climate-control systems of mobile working machines, if both sufficient source temperature and usable thermal power are available. This study re-analyses 64 previously published operating points of a renewable air-cooling unit comprising a desiccant wheel and a dew-point indirect evaporative cooler. Measured or published air states and volumetric flows were reconciled to calculate conditional heating-coil requirements for a nominal 60 °C outlet temperature. Supplementary outlet-temperature ranges from separate experiments were transferred only to 30 cases with exactly matching published inlet settings. Nominal demand ranged from 6.30 to 23.81 kW (median 13.29 kW); the remaining 34 cases had no supplementary temperature ranges. A consistency audit found that system-level process/regeneration moisture-indicator ratios were within ±10% of unity in only 8 of 64 cases and that the reconstructed 5–7 enthalpy change exceeded conditional 5–6 heating demand in 15 cases. These comparisons identify unresolved boundary/state limitations, not proven violations of conservation. Illustrative input-perturbation calculations were reported separately from experimental uncertainty. The resulting heating demands and source-screening inequalities are necessary conditional references, not measured recovered heat, demonstrated engine integration, COP improvement or fuel savings.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-27
DOI
https://doi.org/10.3390/en19235759
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Waste Heat Recovery Limits for Energy-Efficient Climate Control in Mobile Working Machines

Zdzisław Kaliniewicz, Magdalena Lemecha, Piotr Markowski, Jan Bocianowski et al.
Energies
Adsorption and Cooling Systems
article

Waste Heat Recovery Limits for Energy-Efficient Climate Control in Mobile Working Machines

Zdzisław Kaliniewicz, Magdalena Lemecha, Piotr Markowski, Jan Bocianowski, K. Durczak, María Jesús Romero-Lara
article en

Abstract

Low-grade waste heat may potentially support desiccant regeneration in the climate-control systems of mobile working machines, if both sufficient source temperature and usable thermal power are available. This study re-analyses 64 previously published operating points of a renewable air-cooling unit comprising a desiccant wheel and a dew-point indirect evaporative cooler. Measured or published air states and volumetric flows were reconciled to calculate conditional heating-coil requirements for a nominal 60 °C outlet temperature. Supplementary outlet-temperature ranges from separate experiments were transferred only to 30 cases with exactly matching published inlet settings. Nominal demand ranged from 6.30 to 23.81 kW (median 13.29 kW); the remaining 34 cases had no supplementary temperature ranges. A consistency audit found that system-level process/regeneration moisture-indicator ratios were within ±10% of unity in only 8 of 64 cases and that the reconstructed 5–7 enthalpy change exceeded conditional 5–6 heating demand in 15 cases. These comparisons identify unresolved boundary/state limitations, not proven violations of conservation. Illustrative input-perturbation calculations were reported separately from experimental uncertainty. The resulting heating demands and source-screening inequalities are necessary conditional references, not measured recovered heat, demonstrated engine integration, COP improvement or fuel savings.

EnergiesVol. 19(23)
University of Warmia and Mazury in Olsztyn (PL), University of Córdoba (ES), University of Life Sciences in Poznań (PL)
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Waste Heat Recovery Limits for Energy-Efficient Climate Control in Mobile Working Machines — Zdzisław Kaliniewicz, Magdalena Lemecha, et al. · Energies (2026) | TGRS Research Map | TGRS