Assessment of Urban Park Cooling Effects and Their Influencing Factors: A Case Study of Zhengzhou, China

Rapid urban expansion has increasingly intensified the urban heat island (UHI) effect, while parks and green spaces play an important role in mitigating this phenomenon. However, as land resources become increasingly limited, the unrestricted expansion of blue-green spaces is not a viable solution. Focusing on the central urban area of Zhengzhou, this study analyzed the summer cooling effects of 51 urban parks by quantifying four indicators derived from retrieved land surface temperature (LST) data: Park Cooling Intensity (PCI), Park Cooling Area (PCA), Park Cooling Efficiency (PCE), and Park Cooling Gradient (PCG). Correlation analyses were further conducted to examine the relationships between cooling indicators and influencing factors such as park area, perimeter, and the proportions of vegetation and water bodies. Cluster analysis was then used to classify parks according to their cooling characteristics, while random forest analysis was employed to identify the relative importance of different influencing factors. The results show that: (1) 45 of the 51 parks exhibited cooling effects, with mean values of PCI, PCA, PCE, and PCG of 2.88 °C, 284.02 ha, 13.94, and 6.97 °C/km, respectively, among the parks with cooling capacity; (2) park area and perimeter showed significant positive correlations with PCA, with the park area threshold based on PCA being approximately 127.75 ha; (3) cluster analysis identified four types of parks with varying cooling characteristics, among which Bundle 2 exhibited the strongest overall cooling performance, whereas Bundle 4 showed the weakest overall cooling performance; and (4) random forest analysis indicated that park cooling effects were jointly influenced by park characteristics and the surrounding built environment, with different cooling indicators showing distinct responses to the influencing factors. These findings can provide insights into variations in urban park cooling performance and inform park planning and landscape optimization under conditions of limited urban land resources.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2026-11-27
DOI
https://doi.org/10.3390/atmos17121178
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessment of Urban Park Cooling Effects and Their Influencing Factors: A Case Study of Zhengzhou, China

Shaomian Niu, Xin Yao, Fangyuan Huang, Feng Xu
Atmosphere
Urban Heat Island Mitigation
article

Assessment of Urban Park Cooling Effects and Their Influencing Factors: A Case Study of Zhengzhou, China

Shaomian Niu, Xin Yao, Fangyuan Huang, Feng Xu
article en

Abstract

Rapid urban expansion has increasingly intensified the urban heat island (UHI) effect, while parks and green spaces play an important role in mitigating this phenomenon. However, as land resources become increasingly limited, the unrestricted expansion of blue-green spaces is not a viable solution. Focusing on the central urban area of Zhengzhou, this study analyzed the summer cooling effects of 51 urban parks by quantifying four indicators derived from retrieved land surface temperature (LST) data: Park Cooling Intensity (PCI), Park Cooling Area (PCA), Park Cooling Efficiency (PCE), and Park Cooling Gradient (PCG). Correlation analyses were further conducted to examine the relationships between cooling indicators and influencing factors such as park area, perimeter, and the proportions of vegetation and water bodies. Cluster analysis was then used to classify parks according to their cooling characteristics, while random forest analysis was employed to identify the relative importance of different influencing factors. The results show that: (1) 45 of the 51 parks exhibited cooling effects, with mean values of PCI, PCA, PCE, and PCG of 2.88 °C, 284.02 ha, 13.94, and 6.97 °C/km, respectively, among the parks with cooling capacity; (2) park area and perimeter showed significant positive correlations with PCA, with the park area threshold based on PCA being approximately 127.75 ha; (3) cluster analysis identified four types of parks with varying cooling characteristics, among which Bundle 2 exhibited the strongest overall cooling performance, whereas Bundle 4 showed the weakest overall cooling performance; and (4) random forest analysis indicated that park cooling effects were jointly influenced by park characteristics and the surrounding built environment, with different cooling indicators showing distinct responses to the influencing factors. These findings can provide insights into variations in urban park cooling performance and inform park planning and landscape optimization under conditions of limited urban land resources.

AtmosphereVol. 17(12)
Xinyang Normal University (CN)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon