Background Liquefaction-induced uplift of sewer manholes is a recurrent form of earthquake damage to urban lifelines. Uplifted manholes obstruct roads needed for evacuation and emergency response, and damaged manholes interrupt wastewater service during recovery. Because manholes are numerous and lie beneath roads in service, pre-earthquake countermeasures must be quick to install with limited excavation. This study examines a retrofit in which a weight collar of precast rings and mortar is installed from the road surface around the top 425 mm of an existing manhole. Results Paired 1-g shaking table tests were conducted on 1/20-scale models of a standard No. 1 manhole. The models were embedded side by side in loose, nominally saturated silica sand (relative density 38–40%) with the groundwater table at the ground surface and were shaken sinusoidally at 3 Hz with nominal amplitudes of 0.5, 1.0, and 1.5 m/s 2. The unweighted model was uplifted by 9.6–14.0 mm (8–12% of its height) after a substantial buildup of excess pore water pressure. The model with the collar showed no measurable uplift. Because the surrounding ground settled by 11–14 mm, it still protruded by an estimated 10–13 mm above the mean settled surface, about half that of the unweighted model. Because the collar changed both mass and geometry, the response cannot be attributed to the added weight alone. A limit equilibrium interpretation, conditional on a back-calculated equivalent excess pore water pressure ratio of about 0.45–0.55, gives factors of safety close to unity (0.95–1.09) for the weighted model. In an illustrative prototype calculation, three rings raised the factor of safety at full liquefaction from 0.76 to 1.09 for a groundwater table depth of 1.0 m, but only from 0.55 to 0.72 when the collar was submerged. Conclusions The tests provide exploratory evidence that a surface-installed weight collar can suppress one damage mode, absolute uplift, under the tested small-scale conditions. Residual protrusion, pipe connections, and groundwater conditions remain decisive for post-earthquake road and sewer functionality. A three-step screening procedure based on the consequence of failure, the seasonal high groundwater level, and the required functional performance is proposed for prioritizing retrofit sites.
Authors
- Khin Nyein Chan Kyaw
- Shinya Inazumi (ORCID: https://orcid.org/0000-0002-5639-5254)
- Daiki Fujita
Institutions
- Shibaura Institute of Technology (JP)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-27
- DOI
- https://doi.org/10.21203/rs.3.rs-11763832/v1
- Primary Topic
- Geotechnical Engineering and Underground Structures
- Type
- preprint