Development of Vascular-Inspired Crack-Pore Connectivity in Aged Concrete through Chemical Treatment: Toward Repair-Oriented Applications

In aged concrete structures, subsurface crack networks are often difficult to reach for repair purposes. This study investigates the use of controlled chemical treatment, combined with an artificial mono-drilled channel, to enhance the connectivity between surface-accessible channels and an internal inaccessible cracks/pores network. The connected channel with cracks/pores networks can then serve as a vascular network for efficient delivery of repair agents. Polyethylene glycol (PEG) solutions and deionized water (DIW) are used as leaching reagents to create vascular networks. The influence of treatment on creating a vascular network was evaluated using X-ray nano-computed tomography, which demonstrated enhanced connectivity with subsurface cracks/pores after chemical treatments due to accelerated portlandite leaching, which was observed using thermogravimetric analysis. In addition, dynamic vapor sorption analysis also confirmed an increase in porosity, especially finer pores including gel and mesopore regions, to facilitate the network formation. Furthermore, the effect of chemical treatment on concrete mechanical strength was assessed after controlled treatment with varying PEG concentrations (5% and 10%) and DIW for 1, 2, and 4 h. The results indicated that after 1 h of chemical treatment, the compressive strength was comparable to the control sample, with slight improvements observed after 2 h of 5% PEG treatment. However, after 4 h, treatment with both PEG and DIW led to a reduction in compressive strength attributed to excess portlandite leaching, which likely increased porosity. Chemical treatment in aged concrete is generally considered high risk due to its complex and often unpredictable interaction with the concrete microstructure and existing material properties. Incompatibility or improper application can lead to additional cracking or a reduction in structural performance. Despite these risks, when the treatment is applied in a controlled manner, as shown in this study, it offers a promising approach to reach subsurface cracks/pores for repair-oriented applications.

Authors

Institutions

Publication Details

Journal
Journal of Materials in Civil Engineering
Published
2026-11-27
DOI
https://doi.org/10.1061/jmcee7.mteng-24526
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of Vascular-Inspired Crack-Pore Connectivity in Aged Concrete through Chemical Treatment: Toward Repair-Oriented Applications

Hsiao Wei Lee, Christopher M. Sales, Mija H. Hubler, Yaghoob Amir Farnam et al.
Journal of Materials in Civil Engineering
Concrete Corrosion and Durability
article

Development of Vascular-Inspired Crack-Pore Connectivity in Aged Concrete through Chemical Treatment: Toward Repair-Oriented Applications

Hsiao Wei Lee, Christopher M. Sales, Mija H. Hubler, Yaghoob Amir Farnam, Ahmad R. Najafi, Mohammad Irfan Iqbal, Geetika Mishra, Noelle Lilan
article en

Abstract

In aged concrete structures, subsurface crack networks are often difficult to reach for repair purposes. This study investigates the use of controlled chemical treatment, combined with an artificial mono-drilled channel, to enhance the connectivity between surface-accessible channels and an internal inaccessible cracks/pores network. The connected channel with cracks/pores networks can then serve as a vascular network for efficient delivery of repair agents. Polyethylene glycol (PEG) solutions and deionized water (DIW) are used as leaching reagents to create vascular networks. The influence of treatment on creating a vascular network was evaluated using X-ray nano-computed tomography, which demonstrated enhanced connectivity with subsurface cracks/pores after chemical treatments due to accelerated portlandite leaching, which was observed using thermogravimetric analysis. In addition, dynamic vapor sorption analysis also confirmed an increase in porosity, especially finer pores including gel and mesopore regions, to facilitate the network formation. Furthermore, the effect of chemical treatment on concrete mechanical strength was assessed after controlled treatment with varying PEG concentrations (5% and 10%) and DIW for 1, 2, and 4 h. The results indicated that after 1 h of chemical treatment, the compressive strength was comparable to the control sample, with slight improvements observed after 2 h of 5% PEG treatment. However, after 4 h, treatment with both PEG and DIW led to a reduction in compressive strength attributed to excess portlandite leaching, which likely increased porosity. Chemical treatment in aged concrete is generally considered high risk due to its complex and often unpredictable interaction with the concrete microstructure and existing material properties. Incompatibility or improper application can lead to additional cracking or a reduction in structural performance. Despite these risks, when the treatment is applied in a controlled manner, as shown in this study, it offers a promising approach to reach subsurface cracks/pores for repair-oriented applications.

Journal of Materials in Civil EngineeringVol. 39(4)
University of Colorado Boulder (US), Drexel University (US), National Cheng Kung University (TW)
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon