End‐Organ Dysfunction and Postprocedural Perfusion Pressure in Relation to Mortality After Mitral Transcatheter Edge‐to‐Edge Repair

BACKGROUND: Outcomes after mitral transcatheter edge-to-edge repair (M-TEER) remain variable despite adequate mitral regurgitation reduction. Baseline end-organ dysfunction and the immediate postprocedural pressure state may capture complementary phases of risk. We assessed long-term mortality by integrating baseline MELD-XI with immediate postprocedural perfusion pressure (PP). AIMS: We aimed to assess the association of baseline MELD-XI and immediate postprocedural perfusion pressure (PP), individually and in combination, with long-term mortality after M-TEER. METHODS: This single-center retrospective study included 238 patients undergoing M-TEER. PP was calculated as mean arterial pressure (MAP) minus central venous pressure (CVP) immediately after the procedure. PP and MELD-XI were analyzed as continuous variables, with prespecified thresholds of PP 60 mmHg and MELD-XI 11 used for grouped risk stratification. RESULTS: During a median follow-up of 730 days, 77 patients died. Lower PP (adjusted hazard ratio [HR] per 10 mm Hg increase, 0.684; 95% confidence interval [CI], 0.572-0.818; p < 0.001) and higher MELD-XI (adjusted HR per 1-point increase, 1.072; 95% CI, 1.014-1.132; p = 0.014) were independently associated with mortality. Compared with high PP/low MELD-XI, risk was highest with low PP/high MELD-XI (adjusted HR, 7.80; 95% CI, 3.78-16.10; p < 0.001) and was also increased with low PP/low MELD-XI (adjusted HR, 2.84; 95% CI, 1.53-5.29; p < 0.001). PP and MAP had similar prognostic performance, whereas CVP was not independently associated with mortality. CONCLUSIONS: Integrating baseline organ status with procedure-end perfusion identified a high-risk phenotype after M-TEER. Patients with elevated MELD-XI and low PP had the poorest survival. PP did not outperform MAP, indicating a predominantly arterial-pressure signal.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-11-27
DOI
https://doi.org/10.1002/ccd.71070
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

End‐Organ Dysfunction and Postprocedural Perfusion Pressure in Relation to Mortality After Mitral Transcatheter Edge‐to‐Edge Repair

Takao Morikawa, Fumiya Hasegawa, Tomofumi Nakatsukasa, Ryo Shigeno et al.
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

End‐Organ Dysfunction and Postprocedural Perfusion Pressure in Relation to Mortality After Mitral Transcatheter Edge‐to‐Edge Repair

Takao Morikawa, Fumiya Hasegawa, Tomofumi Nakatsukasa, Ryo Shigeno, Atsushi Hirohata, Takaaki Sato
article en

Abstract

BACKGROUND: Outcomes after mitral transcatheter edge-to-edge repair (M-TEER) remain variable despite adequate mitral regurgitation reduction. Baseline end-organ dysfunction and the immediate postprocedural pressure state may capture complementary phases of risk. We assessed long-term mortality by integrating baseline MELD-XI with immediate postprocedural perfusion pressure (PP). AIMS: We aimed to assess the association of baseline MELD-XI and immediate postprocedural perfusion pressure (PP), individually and in combination, with long-term mortality after M-TEER. METHODS: This single-center retrospective study included 238 patients undergoing M-TEER. PP was calculated as mean arterial pressure (MAP) minus central venous pressure (CVP) immediately after the procedure. PP and MELD-XI were analyzed as continuous variables, with prespecified thresholds of PP 60 mmHg and MELD-XI 11 used for grouped risk stratification. RESULTS: During a median follow-up of 730 days, 77 patients died. Lower PP (adjusted hazard ratio [HR] per 10 mm Hg increase, 0.684; 95% confidence interval [CI], 0.572-0.818; p < 0.001) and higher MELD-XI (adjusted HR per 1-point increase, 1.072; 95% CI, 1.014-1.132; p = 0.014) were independently associated with mortality. Compared with high PP/low MELD-XI, risk was highest with low PP/high MELD-XI (adjusted HR, 7.80; 95% CI, 3.78-16.10; p < 0.001) and was also increased with low PP/low MELD-XI (adjusted HR, 2.84; 95% CI, 1.53-5.29; p < 0.001). PP and MAP had similar prognostic performance, whereas CVP was not independently associated with mortality. CONCLUSIONS: Integrating baseline organ status with procedure-end perfusion identified a high-risk phenotype after M-TEER. Patients with elevated MELD-XI and low PP had the poorest survival. PP did not outperform MAP, indicating a predominantly arterial-pressure signal.

Catheterization and Cardiovascular Interventions
Sakakibara Hospital (JP)
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon