Mechanical role of dural structures and tumor material heterogeneity in brain tumor mass effect

Brain tumor growth induces considerable deformation of the surrounding tissue, yet the mechanical contribution of intracranial dural structures and the influence of tumor material heterogeneity on mass effect remain poorly understood. In this study, we developed a heterogeneous finite element model of the brain to investigate the mechanical role of the falx cerebri and tentorium cerebelli and to determine how variations in tumor subregion stiffness influence the mechanical response of the brain. Two complementary analyses were performed. First, synthetic lesion models with and without the falx and tentorium were compared under otherwise identical conditions. Inclusion of these structures produced only minor changes in global displacement magnitude, but substantially altered the spatial distribution of stress. The dural structures acted as stiff internal partitions that limited interhemispheric and supratentorial-infratentorial deformation and modified load transmission throughout the brain. Including the dural structures led to a different pattern of ventricular volume change during tumor growth, with both lateral ventricles compressed in the dura-included model, whereas without the dura the ventricle on the tumor side expanded while the opposite ventricle was compressed. Second, a parametric analysis was performed using MRI-informed patient-specific tumors comprising necrotic tumor core (NTC), contrast-enhancing tumor core (ETC), and peritumoral edema (Ed). Variations in ETC stiffness produced the largest and most spatially distributed changes in displacement and von Mises stress, with stronger effects in ETC-dominant tumors. Edema stiffness produced weaker and more diffuse effects, whereas NTC stiffness mainly affected the principal stretch within the tumor. These findings demonstrate that intracranial dural structures alter the distribution of tumor-induced deformation and stress despite their limited influence on global displacement magnitude. In the patient-specific models, varying the tumor stiffness within its reported range changed the mechanical response by only a few percent, with the ETC having the largest influence.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-27
DOI
https://doi.org/10.64898/2026.11.26.769431
Primary Topic
Elasticity and Material Modeling
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Mechanical role of dural structures and tumor material heterogeneity in brain tumor mass effect

Nicole Tueni, Marco Wittrich, Benedikt Wiestler, Silvia Budday et al.
bioRxiv (Cold Spring Harbor Laboratory)
Elasticity and Material Modeling
preprint

Mechanical role of dural structures and tumor material heterogeneity in brain tumor mass effect

Nicole Tueni, Marco Wittrich, Benedikt Wiestler, Silvia Budday, Jonas Weidner
preprint en

Abstract

Brain tumor growth induces considerable deformation of the surrounding tissue, yet the mechanical contribution of intracranial dural structures and the influence of tumor material heterogeneity on mass effect remain poorly understood. In this study, we developed a heterogeneous finite element model of the brain to investigate the mechanical role of the falx cerebri and tentorium cerebelli and to determine how variations in tumor subregion stiffness influence the mechanical response of the brain. Two complementary analyses were performed. First, synthetic lesion models with and without the falx and tentorium were compared under otherwise identical conditions. Inclusion of these structures produced only minor changes in global displacement magnitude, but substantially altered the spatial distribution of stress. The dural structures acted as stiff internal partitions that limited interhemispheric and supratentorial-infratentorial deformation and modified load transmission throughout the brain. Including the dural structures led to a different pattern of ventricular volume change during tumor growth, with both lateral ventricles compressed in the dura-included model, whereas without the dura the ventricle on the tumor side expanded while the opposite ventricle was compressed. Second, a parametric analysis was performed using MRI-informed patient-specific tumors comprising necrotic tumor core (NTC), contrast-enhancing tumor core (ETC), and peritumoral edema (Ed). Variations in ETC stiffness produced the largest and most spatially distributed changes in displacement and von Mises stress, with stronger effects in ETC-dominant tumors. Edema stiffness produced weaker and more diffuse effects, whereas NTC stiffness mainly affected the principal stretch within the tumor. These findings demonstrate that intracranial dural structures alter the distribution of tumor-induced deformation and stress despite their limited influence on global displacement magnitude. In the patient-specific models, varying the tumor stiffness within its reported range changed the mechanical response by only a few percent, with the ETC having the largest influence.

bioRxiv (Cold Spring Harbor Laboratory)
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Technical University of Munich (DE)
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon