Resolving Power Quality Issues Using Convolutional Neural Network Based Fuzzy Logic Controlled Dstatcom

Power quality (PQ) disturbances like voltage sag, swell, harmonic and reactive power imbalance vehemently influence reliability and performance of contemporary power distribution systems. Distribution Static Compensator (DSTATCOM) has appeared to be efficient custom power device for reducing and mitigating these issues. Conventional control techniques like Proportional-Integral (PI) controllers always battle with parameter tuning, nonlinear dynamics, and adaptability to rapidly varying grid conditions. This paper describes a hybridized convolutional neural network based fuzzy logic controlled DSTATCOM for resolving power quality problems using reactive current reference control algorithm at distribution corridor. DSTATCOM is used to give out reactive power compensation and grid power factor (PF) correction at point of common coupling (PCC) with changing load condition. Targeted algorithm uplifts transient condition with supervisory fuzzy logic control which reduces DSTATCOM reactive current ripples. DSTATCOM reactive current reference control algorithm was conveyed and performance of the algorithm was obtained using Matlab/Simulink software for steady and transient state situations. Integration of CNN based FLC adaptive compensation for the DSTATCOM to achieve improved power quality and lower THD is the major concern of this approach. The hybridized approach had been proved to portray quicker response and smaller settling time with almost non overshoot when compared with other conventional methods. A remarkable record of total harmonics distortion on voltage (THDV) minimization of 1.14% has been achieved which indicates the approach suitability and superiority in mitigation PQ problems.

Authors

Institutions

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-11-27
DOI
https://doi.org/10.64388/ire1725638
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Resolving Power Quality Issues Using Convolutional Neural Network Based Fuzzy Logic Controlled Dstatcom

Abdurrahman Umar Lawal, Nasiru Bello Kadandani, Ibrahim Haruna Shanono, Bala Boyi Bukata et al.
Iconic Research and Engineering Journals
Power Quality and Harmonics
article

Resolving Power Quality Issues Using Convolutional Neural Network Based Fuzzy Logic Controlled Dstatcom

Abdurrahman Umar Lawal, Nasiru Bello Kadandani, Ibrahim Haruna Shanono, Bala Boyi Bukata, Adamu Sa'idu
article en

Abstract

Power quality (PQ) disturbances like voltage sag, swell, harmonic and reactive power imbalance vehemently influence reliability and performance of contemporary power distribution systems. Distribution Static Compensator (DSTATCOM) has appeared to be efficient custom power device for reducing and mitigating these issues. Conventional control techniques like Proportional-Integral (PI) controllers always battle with parameter tuning, nonlinear dynamics, and adaptability to rapidly varying grid conditions. This paper describes a hybridized convolutional neural network based fuzzy logic controlled DSTATCOM for resolving power quality problems using reactive current reference control algorithm at distribution corridor. DSTATCOM is used to give out reactive power compensation and grid power factor (PF) correction at point of common coupling (PCC) with changing load condition. Targeted algorithm uplifts transient condition with supervisory fuzzy logic control which reduces DSTATCOM reactive current ripples. DSTATCOM reactive current reference control algorithm was conveyed and performance of the algorithm was obtained using Matlab/Simulink software for steady and transient state situations. Integration of CNN based FLC adaptive compensation for the DSTATCOM to achieve improved power quality and lower THD is the major concern of this approach. The hybridized approach had been proved to portray quicker response and smaller settling time with almost non overshoot when compared with other conventional methods. A remarkable record of total harmonics distortion on voltage (THDV) minimization of 1.14% has been achieved which indicates the approach suitability and superiority in mitigation PQ problems.

Iconic Research and Engineering JournalsVol. 10(5)
Federal College of Education (Technical) Bichi (NG), Bayero University Kano (NG)
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon