What Anchor Calibration Cannot Fix: Tag-, Orientation- and Placement-Dependent Bias in Low-Cost UWB TDOA Positioning, with Implications for Wearable Occupational Safety Systems

Receiver-side ultra-wideband (UWB) time-difference-of-arrival (TDOA) positioning suits worker safety wearables, yet reported accuracies come from short recordings with one tag in one orientation. We ran a static campaign of more than 120 h with a low-cost TDOA system at laser-surveyed office points, with rotations of tags across points, tag rotation, a person near the tags and interleaved two-way ranging. Tags lay on desks; one was also worn in a static test. The error at a point was stable within 1–4 cm over hours but depended on the tag–placement combination: across four tags rotated through four points, median errors spanned 27 cm by tag and 42 cm by point, and untouched tags shifted by up to 49 cm within a month. Rotating tags shifted their median error by 12–79 cm; repositioning a tag on the same mark shifted it by 4–50 cm. Fixed per-anchor calibration gave no consistent benefit. Offsets estimated from one tag’s data improved that tag overnight (14–47 to 9–17 cm) but gave 73–114 cm after rotation. A nearby person changed the error in either direction, and the residual rose only in some geometries. Warning margins should use error distributions resolved by tag, orientation and placement; on-body validation remains necessary.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-27
DOI
https://doi.org/10.3390/s26237508
Primary Topic
Indoor and Outdoor Localization Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

What Anchor Calibration Cannot Fix: Tag-, Orientation- and Placement-Dependent Bias in Low-Cost UWB TDOA Positioning, with Implications for Wearable Occupational Safety Systems

Fırat Kaçar, Eren Mert
Sensors
Indoor and Outdoor Localization Technologies
article

What Anchor Calibration Cannot Fix: Tag-, Orientation- and Placement-Dependent Bias in Low-Cost UWB TDOA Positioning, with Implications for Wearable Occupational Safety Systems

Fırat Kaçar, Eren Mert
article en

Abstract

Receiver-side ultra-wideband (UWB) time-difference-of-arrival (TDOA) positioning suits worker safety wearables, yet reported accuracies come from short recordings with one tag in one orientation. We ran a static campaign of more than 120 h with a low-cost TDOA system at laser-surveyed office points, with rotations of tags across points, tag rotation, a person near the tags and interleaved two-way ranging. Tags lay on desks; one was also worn in a static test. The error at a point was stable within 1–4 cm over hours but depended on the tag–placement combination: across four tags rotated through four points, median errors spanned 27 cm by tag and 42 cm by point, and untouched tags shifted by up to 49 cm within a month. Rotating tags shifted their median error by 12–79 cm; repositioning a tag on the same mark shifted it by 4–50 cm. Fixed per-anchor calibration gave no consistent benefit. Offsets estimated from one tag’s data improved that tag overnight (14–47 to 9–17 cm) but gave 73–114 cm after rotation. A nearby person changed the error in either direction, and the residual rose only in some geometries. Warning margins should use error distributions resolved by tag, orientation and placement; on-body validation remains necessary.

SensorsVol. 26(23)
Istanbul University-Cerrahpaşa (TR), Istanbul University (TR)
Indoor and Outdoor Localization Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
What Anchor Calibration Cannot Fix: Tag-, Orientation- and Placement-Dependent Bias in Low-Cost UWB TDOA Positioning, with Implications for Wearable Occupational Safety Systems — Fırat Kaçar, Eren Mert · Sensors (2026) | TGRS Research Map | TGRS