Resistivity Asymmetry in Deep Geothermal Sedimentary Formations: Multi-Well Log Analysis and LLM-Assisted Interpretation

In deep sedimentary formations, intervals with similar lithology and estimated temperature can display sharply different resistivities, sometimes spanning several orders of magnitude. Here, electrical asymmetry refers to the resistivity contrast between intervals assigned comparable lithological and thermal descriptors. The dataset combines resistivity logs, mud-logging records, and temperature measurements from 13 deep wells. After excluding non-sedimentary rock records and screening for extreme resistivity values and unusually thick intervals, 11,085 intervals were retained for statistical analysis. We compared lithology-specific resistivity quantiles and progressively matched intervals by well, lithology, stratigraphic unit, estimated temperature, and logging curve. The median resistivities of mudstone, sandstone, sandy mudstone, and gypsum- and salt-bearing mudstone were 3.97, 4.92, 2.87, and 5.18 Ω·m, respectively, although their resistivity distributions overlapped considerably. The higher median Rt in the T ≥ 170 °C group was sensitive to the wells represented in that group. Among 193 within-well groups, 104 showed Q75/Q25 ≥ 2. Six matched well pairs showed median Rt contrasts of 6.2–93.1 times. Based on these statistical patterns, three well intervals exhibiting distinct electrical characteristics were selected for geological interpretation. DeepSeek-V4.1-Flash-1017 (Non-thinking Mode) and Kimi-K2.6 (Advanced Reasoning) independently interpreted three representative intervals using the same input structure. Across five independent runs per model and interval (30 replies), the quantile-based classifications remained consistent, whereas the proposed geological explanations varied. The findings indicate that resistivity differentiation in deep sedimentary formations is not confined to contrasts between lithological classes. Such variations may be associated with differences in electrical conduction conditions within the formations, while the sources of the resistivity logging curves may also contribute to the observed contrasts. Lithological classification and estimated temperature alone are therefore insufficient to determine the electrical characteristics of an individual well interval.

Authors

Institutions

Publication Details

Journal
Symmetry
Published
2026-11-27
DOI
https://doi.org/10.3390/sym18121990
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Resistivity Asymmetry in Deep Geothermal Sedimentary Formations: Multi-Well Log Analysis and LLM-Assisted Interpretation

Taping He, Yuehan Shang, Xiaoxin Shi, Yaoqi Zhou et al.
Symmetry
Geophysical and Geoelectrical Methods
article

Resistivity Asymmetry in Deep Geothermal Sedimentary Formations: Multi-Well Log Analysis and LLM-Assisted Interpretation

Taping He, Yuehan Shang, Xiaoxin Shi, Yaoqi Zhou, Yue Zhang
article en

Abstract

In deep sedimentary formations, intervals with similar lithology and estimated temperature can display sharply different resistivities, sometimes spanning several orders of magnitude. Here, electrical asymmetry refers to the resistivity contrast between intervals assigned comparable lithological and thermal descriptors. The dataset combines resistivity logs, mud-logging records, and temperature measurements from 13 deep wells. After excluding non-sedimentary rock records and screening for extreme resistivity values and unusually thick intervals, 11,085 intervals were retained for statistical analysis. We compared lithology-specific resistivity quantiles and progressively matched intervals by well, lithology, stratigraphic unit, estimated temperature, and logging curve. The median resistivities of mudstone, sandstone, sandy mudstone, and gypsum- and salt-bearing mudstone were 3.97, 4.92, 2.87, and 5.18 Ω·m, respectively, although their resistivity distributions overlapped considerably. The higher median Rt in the T ≥ 170 °C group was sensitive to the wells represented in that group. Among 193 within-well groups, 104 showed Q75/Q25 ≥ 2. Six matched well pairs showed median Rt contrasts of 6.2–93.1 times. Based on these statistical patterns, three well intervals exhibiting distinct electrical characteristics were selected for geological interpretation. DeepSeek-V4.1-Flash-1017 (Non-thinking Mode) and Kimi-K2.6 (Advanced Reasoning) independently interpreted three representative intervals using the same input structure. Across five independent runs per model and interval (30 replies), the quantile-based classifications remained consistent, whereas the proposed geological explanations varied. The findings indicate that resistivity differentiation in deep sedimentary formations is not confined to contrasts between lithological classes. Such variations may be associated with differences in electrical conduction conditions within the formations, while the sources of the resistivity logging curves may also contribute to the observed contrasts. Lithological classification and estimated temperature alone are therefore insufficient to determine the electrical characteristics of an individual well interval.

SymmetryVol. 18(12)
Sinopec (China) (CN), China University of Petroleum, East China (CN)
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon