Novel toilet filtration system for contrast material removal at the source: first outpatient results

Objectives Iodinated contrast media (ICM) are essential for diagnostic imaging but impose a substantial environmental burden due to their widespread use. This prospective observational study evaluates the efficiency of a novel toilet filtration system (TFS) for recovering ICM after contrast-enhanced CT (ceCT) and explores factors that contribute to successful implementation of the system. Materials and methods This prospective observational study included consecutive outpatients scheduled for ceCT using Iomeprol as ICM. Patients were informed about the TFS, ICM excretion, and environmental implications. They were asked to wait at least 30 min after scanning and to use the TFS for their first post-ceCT urination. The removal efficiency of the TFS was determined by measuring ICM concentrations in influent and effluent streams. The proportion of administered ICM recovered was calculated from the cartridge’s contents. Results Of 395 consecutive patients undergoing ceCT, 277 (70%) consented to participate, and 273 patients (median age 65.5; IQR: 57.2–73.4; 151 men) successfully used the TFS. The median interval between contrast administration and urination was 36 min (IQR: 31–41). Most patients (81%) waited at least 30 min before voiding. Removal efficiency of the TFS exceeded 99.9% for ICM. Limited ICM excretion led to recovery of 2.78 kg out of 18.41 kg administered Iomeprol (15.1%; 1.36 kg iodine). Conclusion While ICM is efficiently removed using a novel TFS (> 99.9%), ICM excretion during the 30-min post-examination waiting period was limited. The approach can recover approximately 71 kg of ICM per year per 10,000 ceCT examinations, a number that could be further improved through efforts to increase ICM excretion. Key Points Question TFS have the potential to reduce the amount of contrast media entering wastewater, but their effectiveness is unclear. Findings TFS achieved excellent contrast removal, and was well accepted by patients, but contrast excretion within the median 36-min waiting period is limited to 15%. Critical relevance statement The novel toilet-based filtration system enables substantial iodine recovery from excreted ICM in urine, but limited post-ceCT excretion during short waiting times highlights the need for process adaptations to further increase overall excretion and maximise iodine recovery rates.

Authors

Institutions

Publication Details

Journal
Insights into Imaging
Published
2026-11-27
DOI
https://doi.org/10.1186/s13244-026-02480-5
Primary Topic
Healthcare and Environmental Waste Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Novel toilet filtration system for contrast material removal at the source: first outpatient results

Alex Hol, Mathias Prokop, Helena Maria Dekker, Gerard Stroomberg et al.
Insights into Imaging
Healthcare and Environmental Waste Management
article

Novel toilet filtration system for contrast material removal at the source: first outpatient results

Alex Hol, Mathias Prokop, Helena Maria Dekker, Gerard Stroomberg, Mattijs Maris
article en

Abstract

Objectives Iodinated contrast media (ICM) are essential for diagnostic imaging but impose a substantial environmental burden due to their widespread use. This prospective observational study evaluates the efficiency of a novel toilet filtration system (TFS) for recovering ICM after contrast-enhanced CT (ceCT) and explores factors that contribute to successful implementation of the system. Materials and methods This prospective observational study included consecutive outpatients scheduled for ceCT using Iomeprol as ICM. Patients were informed about the TFS, ICM excretion, and environmental implications. They were asked to wait at least 30 min after scanning and to use the TFS for their first post-ceCT urination. The removal efficiency of the TFS was determined by measuring ICM concentrations in influent and effluent streams. The proportion of administered ICM recovered was calculated from the cartridge’s contents. Results Of 395 consecutive patients undergoing ceCT, 277 (70%) consented to participate, and 273 patients (median age 65.5; IQR: 57.2–73.4; 151 men) successfully used the TFS. The median interval between contrast administration and urination was 36 min (IQR: 31–41). Most patients (81%) waited at least 30 min before voiding. Removal efficiency of the TFS exceeded 99.9% for ICM. Limited ICM excretion led to recovery of 2.78 kg out of 18.41 kg administered Iomeprol (15.1%; 1.36 kg iodine). Conclusion While ICM is efficiently removed using a novel TFS (> 99.9%), ICM excretion during the 30-min post-examination waiting period was limited. The approach can recover approximately 71 kg of ICM per year per 10,000 ceCT examinations, a number that could be further improved through efforts to increase ICM excretion. Key Points Question TFS have the potential to reduce the amount of contrast media entering wastewater, but their effectiveness is unclear. Findings TFS achieved excellent contrast removal, and was well accepted by patients, but contrast excretion within the median 36-min waiting period is limited to 15%. Critical relevance statement The novel toilet-based filtration system enables substantial iodine recovery from excreted ICM in urine, but limited post-ceCT excretion during short waiting times highlights the need for process adaptations to further increase overall excretion and maximise iodine recovery rates.

Insights into ImagingVol. 17(1)
Radboud University Medical Center (NL)
Healthcare and Environmental Waste Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon