A Comparative Evaluation of Multi-Architecture Ordinal Learning for Five-Class Diabetic Retinopathy Grading: Ensemble Performance and Explainability Analysis

Background/Objectives: Diabetic retinopathy (DR) is a major cause of diabetes-related vision loss. Accurate five-class severity grading remains challenging due to class imbalance, the ordered nature of disease severity, and visual similarities between adjacent grades. This study evaluates a multi-architecture ordinal learning framework combining SwinV2, EVA-02, and ConvNeXtV2 with Consistent Rank Logits (CORAL)-based classification. Methods: The models were trained on multiple retinal datasets using Ben Graham preprocessing and APTOS-specific fine-tuning, while four-view test-time augmentation was applied during held-out test inference. Equal-weight soft voting, learned weighting, and stacking were evaluated using out-of-fold (OOF) predictions and nested validation. Performance was assessed through class-specific metrics, ordinal error analysis, and qualitative explanations using Grad-CAM and LIME. Results: The three-model ensemble achieved an OOF Macro-F1 of 0.7419 and Severe-class F1 of 0.5046. Under nested validation, equal-weight soft voting achieved a Macro-F1 of 0.7368 and Severe-class F1 of 0.4880. On the held-out APTOS 2019 test set, the ensemble achieved a Macro-F1 of 0.7263 and Severe-class F1 of 0.4058, compared with 0.7304 and 0.4286 for EVA-02, respectively. Paired bootstrap comparisons showed no statistically significant differences in these test metrics. Error analysis showed that 83.1% of incorrect OOF predictions differed by one severity grade, while 98.5% differed by no more than two grades. The CORAL–Softmax comparison was limited to EVA-02 using a single random seed. Conclusions: The held-out test contained only 39 Severe images, limiting the precision of class-specific estimates. Overall, the findings highlight the importance of rigorous ensemble validation and class-specific evaluation for DR grading.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-27
DOI
https://doi.org/10.3390/diagnostics16234009
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Comparative Evaluation of Multi-Architecture Ordinal Learning for Five-Class Diabetic Retinopathy Grading: Ensemble Performance and Explainability Analysis

Hanan Saleh Alghamdi, Hind Almisbahi, Hissah Alabbadi
Diagnostics
Retinal Imaging and Analysis
article

A Comparative Evaluation of Multi-Architecture Ordinal Learning for Five-Class Diabetic Retinopathy Grading: Ensemble Performance and Explainability Analysis

Hanan Saleh Alghamdi, Hind Almisbahi, Hissah Alabbadi
article en

Abstract

Background/Objectives: Diabetic retinopathy (DR) is a major cause of diabetes-related vision loss. Accurate five-class severity grading remains challenging due to class imbalance, the ordered nature of disease severity, and visual similarities between adjacent grades. This study evaluates a multi-architecture ordinal learning framework combining SwinV2, EVA-02, and ConvNeXtV2 with Consistent Rank Logits (CORAL)-based classification. Methods: The models were trained on multiple retinal datasets using Ben Graham preprocessing and APTOS-specific fine-tuning, while four-view test-time augmentation was applied during held-out test inference. Equal-weight soft voting, learned weighting, and stacking were evaluated using out-of-fold (OOF) predictions and nested validation. Performance was assessed through class-specific metrics, ordinal error analysis, and qualitative explanations using Grad-CAM and LIME. Results: The three-model ensemble achieved an OOF Macro-F1 of 0.7419 and Severe-class F1 of 0.5046. Under nested validation, equal-weight soft voting achieved a Macro-F1 of 0.7368 and Severe-class F1 of 0.4880. On the held-out APTOS 2019 test set, the ensemble achieved a Macro-F1 of 0.7263 and Severe-class F1 of 0.4058, compared with 0.7304 and 0.4286 for EVA-02, respectively. Paired bootstrap comparisons showed no statistically significant differences in these test metrics. Error analysis showed that 83.1% of incorrect OOF predictions differed by one severity grade, while 98.5% differed by no more than two grades. The CORAL–Softmax comparison was limited to EVA-02 using a single random seed. Conclusions: The held-out test contained only 39 Severe images, limiting the precision of class-specific estimates. Overall, the findings highlight the importance of rigorous ensemble validation and class-specific evaluation for DR grading.

DiagnosticsVol. 16(23)
King Abdulaziz University (SA)
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines