A performance index for mechanoluminescent sensor materials: Proposal and application to sensor design for crack propagation and strain-distribution monitoring

Mechanoluminescent (ML) sensing enables direct visualization of mechanical phenomena, including crack propagation and strain distribution. Despite the rapid development of ML materials, no quantitative performance metric has been established to date for ML sensor design and evaluation. Consequently, selecting appropriate sensors for given applications remains challenging. This study proposes a new performance metric, the ML index, which builds on Weber contrast to quantify how effectively loading-induced mechanoluminescence can be distinguished from background afterglow and complex spatial patterns. Using crack monitoring in double cantilever beam (DCB) tests—a representative application in international standards—the performance of an ML sensor was systematically evaluated by controlling the strain-transfer efficiency of the polymer matrix. The proposed ML index successfully normalized fabrication-related variations, such as coating thickness, enabling a quantitative comparison of sensor performance. The ML index at 1000 με (Mi 1000) was selected as a practical parameter for sensor design. Quantitative analysis reveals that while Mi 1000 > 0.5 enables reliable crack-tip monitoring, visualization of distributed strain fields necessitates Mi 1000 > 1. This result agrees with the experimental fact that ML sensors exhibiting Mi 1000 > 2 have been applied to a wide range of monitoring and fracture mechanics applications. Our findings demonstrate that the proposed ML index and Mi 1000 provide practical design guidelines that link ML sensor materials, implementation conditions, and sensing requirements.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
Published
2026-11-27
DOI
https://doi.org/10.1177/14644207261493905
Primary Topic
Polymer composites and self-healing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A performance index for mechanoluminescent sensor materials: Proposal and application to sensor design for crack propagation and strain-distribution monitoring

Yuki Fujio, Nao Terasaki
Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
Polymer composites and self-healing
article

A performance index for mechanoluminescent sensor materials: Proposal and application to sensor design for crack propagation and strain-distribution monitoring

Yuki Fujio, Nao Terasaki
article en

Abstract

Mechanoluminescent (ML) sensing enables direct visualization of mechanical phenomena, including crack propagation and strain distribution. Despite the rapid development of ML materials, no quantitative performance metric has been established to date for ML sensor design and evaluation. Consequently, selecting appropriate sensors for given applications remains challenging. This study proposes a new performance metric, the ML index, which builds on Weber contrast to quantify how effectively loading-induced mechanoluminescence can be distinguished from background afterglow and complex spatial patterns. Using crack monitoring in double cantilever beam (DCB) tests—a representative application in international standards—the performance of an ML sensor was systematically evaluated by controlling the strain-transfer efficiency of the polymer matrix. The proposed ML index successfully normalized fabrication-related variations, such as coating thickness, enabling a quantitative comparison of sensor performance. The ML index at 1000 με (Mi 1000) was selected as a practical parameter for sensor design. Quantitative analysis reveals that while Mi 1000 > 0.5 enables reliable crack-tip monitoring, visualization of distributed strain fields necessitates Mi 1000 > 1. This result agrees with the experimental fact that ML sensors exhibiting Mi 1000 > 2 have been applied to a wide range of monitoring and fracture mechanics applications. Our findings demonstrate that the proposed ML index and Mi 1000 provide practical design guidelines that link ML sensor materials, implementation conditions, and sensing requirements.

Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
National Institute of Advanced Industrial Science and Technology (JP)
Polymer composites and self-healing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon