Full-Scale Experimental Testing of a Two-Story Cross-Laminated Timber Rocking Wall Structure Incorporating Resilient Diaphragm and Friction Damper Connections

A series of full-scale experimental tests are carried out on a two-story cross-laminated timber (CLT) structure at the University of Auckland, designed with an emphasis on low-damage concept and structural resilience. The design integrates innovative wall-to-floor shear keys, resilient friction hold-downs, and supplementary damage-free friction dampers. The structure is tested under in-plane, out-of-plane, and bidirectional loading to provide a realistic assessment of its seismic performance and overall behavior. The primary objective is to demonstrate the structure’s ability to accommodate large lateral drifts while maintaining full displacement and force compatibility between the gravity and lateral load-resisting systems, without causing damage to the CLT members or yielding in any connections or fasteners. The lateral load-resisting system comprises two 6-m-tall CLT rocking walls utilizing spring friction dampers acting as hold-downs in the longitudinal direction and tension bracing bars with spring friction dampers in the transverse direction. This study presents the observed structural performance and highlights the behavior of the innovative shear key system. The results indicate that the structure exhibits high ductility and sustains multiple cyclic loadings without any reduction in strength or stiffness. All structural members and connections remain elastic, while the resilient joints provide the required ductility. This performance is achieved through the effective functioning of the shear keys, which maintain full displacement and force compatibility between the gravity frame and the lateral load-resisting system.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2026-11-27
DOI
https://doi.org/10.1061/jsendh.steng-16313
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Full-Scale Experimental Testing of a Two-Story Cross-Laminated Timber Rocking Wall Structure Incorporating Resilient Diaphragm and Friction Damper Connections

Ashkan Hashemi, Setu Agarwal, Pierre J. H. Quenneville, Soheil Assadi et al.
Journal of Structural Engineering
Seismic Performance and Analysis
article

Full-Scale Experimental Testing of a Two-Story Cross-Laminated Timber Rocking Wall Structure Incorporating Resilient Diaphragm and Friction Damper Connections

Ashkan Hashemi, Setu Agarwal, Pierre J. H. Quenneville, Soheil Assadi, Alireza Zare
article en

Abstract

A series of full-scale experimental tests are carried out on a two-story cross-laminated timber (CLT) structure at the University of Auckland, designed with an emphasis on low-damage concept and structural resilience. The design integrates innovative wall-to-floor shear keys, resilient friction hold-downs, and supplementary damage-free friction dampers. The structure is tested under in-plane, out-of-plane, and bidirectional loading to provide a realistic assessment of its seismic performance and overall behavior. The primary objective is to demonstrate the structure’s ability to accommodate large lateral drifts while maintaining full displacement and force compatibility between the gravity and lateral load-resisting systems, without causing damage to the CLT members or yielding in any connections or fasteners. The lateral load-resisting system comprises two 6-m-tall CLT rocking walls utilizing spring friction dampers acting as hold-downs in the longitudinal direction and tension bracing bars with spring friction dampers in the transverse direction. This study presents the observed structural performance and highlights the behavior of the innovative shear key system. The results indicate that the structure exhibits high ductility and sustains multiple cyclic loadings without any reduction in strength or stiffness. All structural members and connections remain elastic, while the resilient joints provide the required ductility. This performance is achieved through the effective functioning of the shear keys, which maintain full displacement and force compatibility between the gravity frame and the lateral load-resisting system.

Journal of Structural EngineeringVol. 153(2)
University of Auckland (NZ)
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Full-Scale Experimental Testing of a Two-Story Cross-Laminated Timber Rocking Wall Structure Incorporating Resilient Diaphragm and Friction Damper Connections — Ashkan Hashemi, Setu Agarwal, et al. · Journal of Structural Engineering (2026) | TGRS Research Map | TGRS