Effect of Eyvan Configuration on Indoor Thermal Performance in Traditional Diyarbakır Houses: Field Evidence for Climate-Responsive Passive Design

Traditional architecture in hot–dry regions embodies accumulated climate-responsive design knowledge that can provide useful principles for contemporary passive building design. Among the characteristic spatial elements of traditional Diyarbakır courtyard houses, the eyvan functions as a semi-open transitional space that provides shading and contributes to the thermal moderation of adjacent indoor spaces. However, in contrast to the formal and typological analyses dominant in the literature, quantitative field evidence concerning the influence of eyvan configuration on indoor thermal performance remains limited. This study investigates the thermal performance associated with three eyvan configurations, single-arched, double-arched, and triple-arched, through temperature and relative humidity measurements conducted at 30-min intervals in three traditional Diyarbakır courtyard houses during June–August. The results show that, during peak hours, the indoor temperatures of spaces adjacent to the investigated eyvans were considerably lower than the corresponding outdoor temperatures. Cooling Degree-Hour (CDH) analysis indicated lower summer temperature exceedance in the investigated building with the largest eyvan configuration. However, these differences reflect the combined thermal characteristics of the three buildings rather than the isolated effect of eyvan volume. The observations showed a consistent case-specific trend in which larger eyvan-to-room volume ratios were associated with lower indoor temperatures. These findings provide quantitative field evidence of the thermal benefits associated with a traditional climate-responsive spatial strategy and indicate that principles derived from eyvan design may inform passive cooling approaches in contemporary buildings in hot–dry climates.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-27
DOI
https://doi.org/10.3390/buildings16234761
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of Eyvan Configuration on Indoor Thermal Performance in Traditional Diyarbakır Houses: Field Evidence for Climate-Responsive Passive Design

Berfin GÖKDEMİR, Hasan Yıldızhan, Şefika ERGİN, Arman Ameen et al.
Buildings
Building Energy and Comfort Optimization
article

Effect of Eyvan Configuration on Indoor Thermal Performance in Traditional Diyarbakır Houses: Field Evidence for Climate-Responsive Passive Design

Berfin GÖKDEMİR, Hasan Yıldızhan, Şefika ERGİN, Arman Ameen, İbrahim Halil Şeker
article en

Abstract

Traditional architecture in hot–dry regions embodies accumulated climate-responsive design knowledge that can provide useful principles for contemporary passive building design. Among the characteristic spatial elements of traditional Diyarbakır courtyard houses, the eyvan functions as a semi-open transitional space that provides shading and contributes to the thermal moderation of adjacent indoor spaces. However, in contrast to the formal and typological analyses dominant in the literature, quantitative field evidence concerning the influence of eyvan configuration on indoor thermal performance remains limited. This study investigates the thermal performance associated with three eyvan configurations, single-arched, double-arched, and triple-arched, through temperature and relative humidity measurements conducted at 30-min intervals in three traditional Diyarbakır courtyard houses during June–August. The results show that, during peak hours, the indoor temperatures of spaces adjacent to the investigated eyvans were considerably lower than the corresponding outdoor temperatures. Cooling Degree-Hour (CDH) analysis indicated lower summer temperature exceedance in the investigated building with the largest eyvan configuration. However, these differences reflect the combined thermal characteristics of the three buildings rather than the isolated effect of eyvan volume. The observations showed a consistent case-specific trend in which larger eyvan-to-room volume ratios were associated with lower indoor temperatures. These findings provide quantitative field evidence of the thermal benefits associated with a traditional climate-responsive spatial strategy and indicate that principles derived from eyvan design may inform passive cooling approaches in contemporary buildings in hot–dry climates.

BuildingsVol. 16(23)
Dicle University (TR), Bingöl University (TR), University of Gävle (SE), Adana Science and Technology University (TR)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon