Electrogram–Pressure Discordance: A Window into the Atrialized Right Ventricle in Ebstein Anomaly

A 41-year-old woman with Ebstein anomaly and severe tricuspid regurgitation underwent invasive hemodynamic assessment. Simultaneous intracardiac electrogram and pressure recordings demonstrated ventricular electrical activation despite an atrial-type pressure waveform within the atrialized right ventricle. Sequential catheter advancement documented the transition from atrial electrical and mechanical activity to electrogram–pressure discordance, followed by concordant ventricular electrical and pressure characteristics in the functional right ventricle. This phenomenon reflects preserved ventricular electrical identity despite atrial-like mechanical behavior. Electrogram–pressure correlation provides a physiological adjunct to echocardiographic and anatomical localization, illustrating the distinctive electrical–mechanical dissociation of the atrialized right ventricle in Ebstein anomaly.

Authors

Institutions

Publication Details

Journal
Indian Journal of Clinical Cardiology
Published
2026-11-27
DOI
https://doi.org/10.1177/26324636261507864
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Electrogram–Pressure Discordance: A Window into the Atrialized Right Ventricle in Ebstein Anomaly

PM Kumar, HARIKRISHNAN SIVADASANPILLAI, Pooja Prasad
Indian Journal of Clinical Cardiology
Congenital Heart Disease Studies
article

Electrogram–Pressure Discordance: A Window into the Atrialized Right Ventricle in Ebstein Anomaly

PM Kumar, HARIKRISHNAN SIVADASANPILLAI, Pooja Prasad
article en

Abstract

A 41-year-old woman with Ebstein anomaly and severe tricuspid regurgitation underwent invasive hemodynamic assessment. Simultaneous intracardiac electrogram and pressure recordings demonstrated ventricular electrical activation despite an atrial-type pressure waveform within the atrialized right ventricle. Sequential catheter advancement documented the transition from atrial electrical and mechanical activity to electrogram–pressure discordance, followed by concordant ventricular electrical and pressure characteristics in the functional right ventricle. This phenomenon reflects preserved ventricular electrical identity despite atrial-like mechanical behavior. Electrogram–pressure correlation provides a physiological adjunct to echocardiographic and anatomical localization, illustrating the distinctive electrical–mechanical dissociation of the atrialized right ventricle in Ebstein anomaly.

Indian Journal of Clinical Cardiology
Sree Chitra Thirunal Institute for Medical Sciences and Technology (IN)
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon