The Safety and Efficacy of a Vestibular Implant to Enhance Balance Through Continuous Electrical Stimulation Targeting the Otoliths: Study Protocol for the BionicVEST2 Trial

Background: Bilateral vestibulopathy (BVP) is a chronic disorder characterized by reduced or absent function of the vestibular organs, resulting in significantly impaired balance, gaze stabilization, and quality of life. Despite its debilitating nature, none of the available treatment modalities can restore vestibular function. In recent years, vestibular implants have emerged as a promising treatment. However, a major drawback of vestibular implantation is the concomitant risk of hearing loss. To address this limitation, a novel implant design combined with improved surgical technique has been developed. Methods: This paper describes the protocol for BionicVEST2, a prospective, multicenter study investigating this new implant in eighteen patients with bilateral vestibulopathy. The primary aim of this study is to demonstrate the implant’s preliminary efficacy in improving gait and balance, while also establishing its safety regarding preservation of hearing. Results: This study will evaluate preliminary efficacy using two primary outcomes, the dynamic gait index and the functional gait assessment. The trial seeks to find significant and clinically relevant improvements in FGA and DGI six months after device activation. In addition, safety will be evaluated by monitoring device-related adverse events and by evaluating the change in hearing status using pure-tone audiometry. Conclusions: The BionicVEST2 study aims to address an important unmet therapeutic need of patients with BVP by evaluating the preliminary efficacy and safety of a vestibular implant designed to improve balance function without compromising residual hearing. If proven successful, this could open a new treatment pathway for people with BVP and (near-)normal hearing. Trial registration: ClinicalTrials.gov: NCT06805175.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-27
DOI
https://doi.org/10.3390/jcm15239324
Primary Topic
Vestibular and auditory disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Safety and Efficacy of a Vestibular Implant to Enhance Balance Through Continuous Electrical Stimulation Targeting the Otoliths: Study Protocol for the BionicVEST2 Trial

Morgana Sluydts, Andrzej J. Zarowski, Raquel Manrique‐Huarte, Emmanuel A. M. Mylanus et al.
Journal of Clinical Medicine
Vestibular and auditory disorders
article

The Safety and Efficacy of a Vestibular Implant to Enhance Balance Through Continuous Electrical Stimulation Targeting the Otoliths: Study Protocol for the BionicVEST2 Trial

Morgana Sluydts, Andrzej J. Zarowski, Raquel Manrique‐Huarte, Emmanuel A. M. Mylanus, Remo A. G. J. Arts, R.J. Boekesteijn, Andy J. Beynon, Erika Van Baelen, Jaime Monedero Afonso, Ángel Ramos Macías, Ángel Ramos de Miguel, Manuel Manrique Rodriguez, Susana Benitez Robaina
article en

Abstract

Background: Bilateral vestibulopathy (BVP) is a chronic disorder characterized by reduced or absent function of the vestibular organs, resulting in significantly impaired balance, gaze stabilization, and quality of life. Despite its debilitating nature, none of the available treatment modalities can restore vestibular function. In recent years, vestibular implants have emerged as a promising treatment. However, a major drawback of vestibular implantation is the concomitant risk of hearing loss. To address this limitation, a novel implant design combined with improved surgical technique has been developed. Methods: This paper describes the protocol for BionicVEST2, a prospective, multicenter study investigating this new implant in eighteen patients with bilateral vestibulopathy. The primary aim of this study is to demonstrate the implant’s preliminary efficacy in improving gait and balance, while also establishing its safety regarding preservation of hearing. Results: This study will evaluate preliminary efficacy using two primary outcomes, the dynamic gait index and the functional gait assessment. The trial seeks to find significant and clinically relevant improvements in FGA and DGI six months after device activation. In addition, safety will be evaluated by monitoring device-related adverse events and by evaluating the change in hearing status using pure-tone audiometry. Conclusions: The BionicVEST2 study aims to address an important unmet therapeutic need of patients with BVP by evaluating the preliminary efficacy and safety of a vestibular implant designed to improve balance function without compromising residual hearing. If proven successful, this could open a new treatment pathway for people with BVP and (near-)normal hearing. Trial registration: ClinicalTrials.gov: NCT06805175.

Journal of Clinical MedicineVol. 15(23)
Cochlear (Australia) (AU), Universidad de Las Palmas de Gran Canaria (ES), Radboud University Nijmegen (NL), Hospital Universitario Insular de Gran Canaria (ES), Radboud University Medical Center (NL), Clinica Universidad de Navarra (ES), Universidad de Navarra (ES)
Vestibular and auditory disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon