Histological Investigations and Comparative Analysis of a Novel 455 nm Blue Light Laser

Objectives To histologically evaluate the cutting effects of a novel 455 nm laser across a range of power and distance settings and to compare with a 10,600 nm fiber‐based carbon dioxide (CO 2) laser. Study Design Descriptive study. Setting In vitro. Methods Using the 455 nm blue laser, and 10,600 nm CO 2 laser, a 300 µm fiber was secured at specific distances (range: 1‐5 mm) from ex vivo bovine tongue tissue. The tissue was incised at a constant speed and varying power (5‐20 W). Histologic specimens were stained for hematoxylin and eosin (H&E) and lactate dehydrogenase (LDH). Incision depth and thermal damage were measured and compared across different wavelengths, power, and distances from tissue. Results At 5 W, the average incision depths were 0.448 mm for 455 nm laser and 0.643 mm for 10,600 nm laser (P = .087). At 10 W, average incision depth was 1.01 mm for 455 nm laser and 1.31 mm for 10,6000 nm laser (P = .090). Increasing power to 20 W increased the average incision depth for the 455 nm laser to 1.588 mm (P < .0001). Laser distance from tissue (1‐5 mm) did not significantly impact incision depth. Thermal damage depth of the 455 nm laser averaged 0.470 mm versus 0.150 mm for the 10,600 nm laser (P < .0001). Power adjustments did not significantly alter thermal spread depth for either laser. Conclusion The 455 nm laser demonstrated similar incision depths to the 10,600 nm CO 2 laser at 5 and 10 W, with increasing depth at 15 and 20 W. The 455 nm laser averaged 0.32 mm greater thermal damage depth than the CO 2 laser. Increasing power for 455 nm laser resulted in deeper incisions without a proportional increase in thermal damage, indicating potential use as a cutting laser.

Authors

Institutions

Publication Details

Journal
Otolaryngology
Published
2026-11-27
DOI
https://doi.org/10.1002/ohn.70479
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Histological Investigations and Comparative Analysis of a Novel 455 nm Blue Light Laser

Maxwell Scher, Lauren F. Tracy, Denis C. Lafreniere, Gregory A. Grillone et al.
Otolaryngology
Laser Applications in Dentistry and Medicine
article

Histological Investigations and Comparative Analysis of a Novel 455 nm Blue Light Laser

Maxwell Scher, Lauren F. Tracy, Denis C. Lafreniere, Gregory A. Grillone, Margaret Mills
article en

Abstract

Objectives To histologically evaluate the cutting effects of a novel 455 nm laser across a range of power and distance settings and to compare with a 10,600 nm fiber‐based carbon dioxide (CO 2) laser. Study Design Descriptive study. Setting In vitro. Methods Using the 455 nm blue laser, and 10,600 nm CO 2 laser, a 300 µm fiber was secured at specific distances (range: 1‐5 mm) from ex vivo bovine tongue tissue. The tissue was incised at a constant speed and varying power (5‐20 W). Histologic specimens were stained for hematoxylin and eosin (H&E) and lactate dehydrogenase (LDH). Incision depth and thermal damage were measured and compared across different wavelengths, power, and distances from tissue. Results At 5 W, the average incision depths were 0.448 mm for 455 nm laser and 0.643 mm for 10,600 nm laser (P = .087). At 10 W, average incision depth was 1.01 mm for 455 nm laser and 1.31 mm for 10,6000 nm laser (P = .090). Increasing power to 20 W increased the average incision depth for the 455 nm laser to 1.588 mm (P < .0001). Laser distance from tissue (1‐5 mm) did not significantly impact incision depth. Thermal damage depth of the 455 nm laser averaged 0.470 mm versus 0.150 mm for the 10,600 nm laser (P < .0001). Power adjustments did not significantly alter thermal spread depth for either laser. Conclusion The 455 nm laser demonstrated similar incision depths to the 10,600 nm CO 2 laser at 5 and 10 W, with increasing depth at 15 and 20 W. The 455 nm laser averaged 0.32 mm greater thermal damage depth than the CO 2 laser. Increasing power for 455 nm laser resulted in deeper incisions without a proportional increase in thermal damage, indicating potential use as a cutting laser.

Otolaryngology
Boston University (US), Boston Medical Center (US), University of Connecticut (US), UConn Health (US)
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon