Morphology, elemental composition, and gamma-exposure response of an MXene/Cu-MOF-coated quartz crystal microbalance

The radiation-sensing capability of a functionalized quartz crystal microbalance (QCM) depends on distinguishing irradiation-associated responses from coating equilibration, moisture interactions, and instrumental drift. In this study, bare Cu-MOF and an MXene/Cu-MOF composite were synthesized using the same hydrothermal approach and characterized before and after gamma irradiation using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). The resonance frequency and resonance width of an MXene/Cu-MOF-coated QCM were monitored during 1 h of exposure to a Cs-137 gamma source and for an additional hour following source removal. The EDX spectra exhibited substantial silicon-substrate contributions, while comparisons of Cu/Si ratios showed variations of + 4.9% and − 10.3% without establishing a systematic irradiation-induced compositional change. The QCM exhibited a frequency decrease of 367 Hz during irradiation and a further decrease of 401 Hz following source removal. Resonance broadening from 2.2 to 3.7 kHz and a subsequent abrupt frequency decrease of approximately 332 Hz, accompanied by resonance narrowing, indicated changes in the acoustic response of the composite coating. The persistence of frequency variations after irradiation suggests that coating equilibration and changes in interfacial mechanical properties may contribute substantially to the observed response. During the late monitoring period, the baseline drift and residual standard deviation were approximately − 0.14 Hz min⁻¹ and 2.2 Hz, respectively, corresponding to an estimated noise-based frequency threshold of approximately 7 Hz. These findings highlight the importance of coating stabilization and acoustic characterization in developing MXene/Cu-MOF-functionalized QCM platforms for radiation-sensing applications.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-27
DOI
https://doi.org/10.21203/rs.3.rs-11791218/v1
Primary Topic
Acoustic Wave Resonator Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Morphology, elemental composition, and gamma-exposure response of an MXene/Cu-MOF-coated quartz crystal microbalance

Abeer Al‐Modlej, Abdullah N. Alodhayb, Nadyah Alanazi, Sheren Alsalmi et al.
Research Square
Acoustic Wave Resonator Technologies
preprint

Morphology, elemental composition, and gamma-exposure response of an MXene/Cu-MOF-coated quartz crystal microbalance

Abeer Al‐Modlej, Abdullah N. Alodhayb, Nadyah Alanazi, Sheren Alsalmi, Sawsan Aldusaymani, Reema Alsawuid
preprint en

Abstract

The radiation-sensing capability of a functionalized quartz crystal microbalance (QCM) depends on distinguishing irradiation-associated responses from coating equilibration, moisture interactions, and instrumental drift. In this study, bare Cu-MOF and an MXene/Cu-MOF composite were synthesized using the same hydrothermal approach and characterized before and after gamma irradiation using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). The resonance frequency and resonance width of an MXene/Cu-MOF-coated QCM were monitored during 1 h of exposure to a Cs-137 gamma source and for an additional hour following source removal. The EDX spectra exhibited substantial silicon-substrate contributions, while comparisons of Cu/Si ratios showed variations of + 4.9% and − 10.3% without establishing a systematic irradiation-induced compositional change. The QCM exhibited a frequency decrease of 367 Hz during irradiation and a further decrease of 401 Hz following source removal. Resonance broadening from 2.2 to 3.7 kHz and a subsequent abrupt frequency decrease of approximately 332 Hz, accompanied by resonance narrowing, indicated changes in the acoustic response of the composite coating. The persistence of frequency variations after irradiation suggests that coating equilibration and changes in interfacial mechanical properties may contribute substantially to the observed response. During the late monitoring period, the baseline drift and residual standard deviation were approximately − 0.14 Hz min⁻¹ and 2.2 Hz, respectively, corresponding to an estimated noise-based frequency threshold of approximately 7 Hz. These findings highlight the importance of coating stabilization and acoustic characterization in developing MXene/Cu-MOF-functionalized QCM platforms for radiation-sensing applications.

Research Square
King Saud University (SA)
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon