Architectural self-repair vs. late-pass collapse: How looped transformers guard refusal

Looped (recurrent-depth) transformers reach deep effective computation with compact parameter counts by re-applying a shared block of layers per token. Prior work has focused on their test-time scaling and reasoning dynamics, leaving open how safety mechanisms like refusal and behavioral steering behave across recurrent depth. We run a mechanistic and interventional study of refusal across looped transformer families, contrasting re-read (prelude-restarting) loops (Inkling 2 Mini, Huginn-0125) against carry (pure-recurrence) loops (Ouro-1.4B-Thinking, Ouro-2.6B-Thinking). Extracting pass-specific refusal directions and projecting them out of individual passes or pass subsets on JailbreakBench exposes an architectural split: (1) Architectural self-repair in re-read loops. In Inkling 2 Mini (3 core passes, each restarting from the prelude with gated Attention Residuals), ablating the refusal direction in any single pass leaves refusal intact (0–3/60 harmful compliance vs. 0/60 baseline); breaking refusal requires ablating at least Passes 2 and 3 together (13/60, p = 0.014 vs. p12), matching all-pass ablation (14/60, p = 5.2 × 10⁻⁵). Single-neuron persona steering follows the same Pass-1 shielding (0/24 trait expression, 23–24/24 coherent). In Huginn-0125 (16 prelude-re-injected steps; not safety post-trained, weak baseline 22/60 comply, 24/60 refuse; random 23/60), single final-step (last1: 22/60) and early-quartile (q0: 21/60) ablation also have zero effect, while mid-recurrence multi-step ablation (q2 and not-q3: both 33/60, +18.3 pp) produces the largest compliance shift. (2) Late-pass collapse in carry loops. In Ouro-1.4B-Thinking and Ouro-2.6B-Thinking (4 shared-weight Universal Transformer steps with no prelude re-injection), Pass-0 ablation is largely self-repaired (8/60 comply in both models), whereas ablating a single late pass breaks refusal, reaching 33/60 (u2) in Ouro-1.4B and 32/60 (u3, matching full 4-pass ablation 32/60) in Ouro-2.6B. Cross-pass cosine analysis explains both behaviors: carry loops go through a directional phase transition after Pass 0 (u0-u3 mean cosine 0.341/0.570) before locking onto a shared late-pass refusal subspace (u2-u3 mean cosine 0.969/0.990). (3) Permanent abliteration and early-exit attacks. Permanent shared-weight orthogonalization flips its optimal pass across scale and depth in Ouro: on Ouro-1.4B-Thinking (96 effective layers), u3 is strictly Pareto-optimal (35/60 harmful compliance at −1.67 pp MMLU cost, 66.33% vs. 68.00% baseline), whereas on Ouro-2.6B-Thinking (48 layers × 4 loops = 192 effective layers), u0 is strictly Pareto-optimal (31/60 = 51.7% harmful compliance, 12/20 benign, MMLU 69.67%, +0.33 pp over 69.33% baseline). On Ouro-2.6B, u3 drops MMLU by −10.67 pp (9/60 comply) and mean/span2 drop MMLU by −27.00/−24.33 pp (7/60 and 1/60 comply). Naive mean or SVD shared-weight abliteration breaks down at depth; practitioners need to sweep single-pass directions instead of averaging across passes. On the attack side, prompt-steered early-exit gate attacks on Ouro-1.4B fail to bypass refusal (1–2/60 comply) even after doubling early-exit gate probability via GCG-lite optimization (0.102 → 0.218), because coherence and refusal both emerge at step 1.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-27
DOI
https://doi.org/10.5281/zenodo.24601719
Primary Topic
Adversarial Robustness in Machine Learning
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Architectural self-repair vs. late-pass collapse: How looped transformers guard refusal

Josh C. Simmons
Zenodo (CERN European Organization for Nuclear Research)
Adversarial Robustness in Machine Learning
preprint

Architectural self-repair vs. late-pass collapse: How looped transformers guard refusal

Josh C. Simmons
preprint en

Abstract

Looped (recurrent-depth) transformers reach deep effective computation with compact parameter counts by re-applying a shared block of layers per token. Prior work has focused on their test-time scaling and reasoning dynamics, leaving open how safety mechanisms like refusal and behavioral steering behave across recurrent depth. We run a mechanistic and interventional study of refusal across looped transformer families, contrasting re-read (prelude-restarting) loops (Inkling 2 Mini, Huginn-0125) against carry (pure-recurrence) loops (Ouro-1.4B-Thinking, Ouro-2.6B-Thinking). Extracting pass-specific refusal directions and projecting them out of individual passes or pass subsets on JailbreakBench exposes an architectural split: (1) Architectural self-repair in re-read loops. In Inkling 2 Mini (3 core passes, each restarting from the prelude with gated Attention Residuals), ablating the refusal direction in any single pass leaves refusal intact (0–3/60 harmful compliance vs. 0/60 baseline); breaking refusal requires ablating at least Passes 2 and 3 together (13/60, p = 0.014 vs. p12), matching all-pass ablation (14/60, p = 5.2 × 10⁻⁵). Single-neuron persona steering follows the same Pass-1 shielding (0/24 trait expression, 23–24/24 coherent). In Huginn-0125 (16 prelude-re-injected steps; not safety post-trained, weak baseline 22/60 comply, 24/60 refuse; random 23/60), single final-step (last1: 22/60) and early-quartile (q0: 21/60) ablation also have zero effect, while mid-recurrence multi-step ablation (q2 and not-q3: both 33/60, +18.3 pp) produces the largest compliance shift. (2) Late-pass collapse in carry loops. In Ouro-1.4B-Thinking and Ouro-2.6B-Thinking (4 shared-weight Universal Transformer steps with no prelude re-injection), Pass-0 ablation is largely self-repaired (8/60 comply in both models), whereas ablating a single late pass breaks refusal, reaching 33/60 (u2) in Ouro-1.4B and 32/60 (u3, matching full 4-pass ablation 32/60) in Ouro-2.6B. Cross-pass cosine analysis explains both behaviors: carry loops go through a directional phase transition after Pass 0 (u0-u3 mean cosine 0.341/0.570) before locking onto a shared late-pass refusal subspace (u2-u3 mean cosine 0.969/0.990). (3) Permanent abliteration and early-exit attacks. Permanent shared-weight orthogonalization flips its optimal pass across scale and depth in Ouro: on Ouro-1.4B-Thinking (96 effective layers), u3 is strictly Pareto-optimal (35/60 harmful compliance at −1.67 pp MMLU cost, 66.33% vs. 68.00% baseline), whereas on Ouro-2.6B-Thinking (48 layers × 4 loops = 192 effective layers), u0 is strictly Pareto-optimal (31/60 = 51.7% harmful compliance, 12/20 benign, MMLU 69.67%, +0.33 pp over 69.33% baseline). On Ouro-2.6B, u3 drops MMLU by −10.67 pp (9/60 comply) and mean/span2 drop MMLU by −27.00/−24.33 pp (7/60 and 1/60 comply). Naive mean or SVD shared-weight abliteration breaks down at depth; practitioners need to sweep single-pass directions instead of averaging across passes. On the attack side, prompt-steered early-exit gate attacks on Ouro-1.4B fail to bypass refusal (1–2/60 comply) even after doubling early-exit gate probability via GCG-lite optimization (0.102 → 0.218), because coherence and refusal both emerge at step 1.

Zenodo (CERN European Organization for Nuclear Research)
Adversarial Robustness in Machine Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon