PVDF-based terahertz anti-resonant fiber refractive index sensor utilizing surface plasmon resonance
In this work, a hollow-core anti-resonant fibre (HC-ARF) refractive index sensor operating in the terahertz (THz) band is proposed. The sensor is constructed on a TOPAS substrate and utilizes the surface plasmon resonance (SPR) effect induced by polyvinylidene fluoride (PVDF). The sensing characteristics for analytes with different refractive indices are systematically investigated by examining the influence of key structural parameters using the full-vector finite element method. The results show that the proposed sensor exhibits excellent sensing capability for analytes with refractive indices ranging from 1.16 to 1.24. A maximum sensitivity of 728.45 GHz/RIU and a figure of merit (FOM) of 64.69 RIU−1 are achieved. In addition, a ± 3% fabrication tolerance analysis indicates that dimensional variations have a negligible impact on the sensing response of the device. The proposed refractive index sensor provides a reliable approach for biomedical sensing in the THz frequency band.
Authors
- 韩颖 Ying Han
- Shi Qiu (ORCID: https://orcid.org/0000-0001-5272-931X)
- Wei Wang (ORCID: https://orcid.org/0000-0003-1780-5545)
- Zihong Lan
- Shuguang Li
- Zifu Zhou
- Shiwen Pan
- Shiwei Liang
Institutions
- Yanshan University (CN)
Publication Details
- Journal
- Journal of Modern Optics
- Published
- 2026-11-27
- DOI
- https://doi.org/10.1080/09500340.2026.2769490
- Primary Topic
- Advanced Fiber Optic Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00