Optimisation of femtosecond dispersion compensation at the sample using side-view two-photon fluorescence imaging

Efficient two-photon absorption depends on compensating the dispersion of the whole excitation path. Building on established fluorescence-based adjustment, we describe a practical procedure that uses side-view images of fluorescence in a dye cuvette, independently of the microscope's scanning and detection, with reference records, stability warnings and open analysis software. For a 1045 nm laser, maxima lay between 21 and 24 screw turns in 11 of 13 sweeps. For a 920 nm laser, fluorescence maxima at the sample differed by 1.63 kfs^2 on average from autocorrelation minima before the scan optics. The recordings also show limitations from signal instability and proximity to clipping. The procedure targets two-photon microscopes for in vivo imaging, such as of neuronal activity, where tissue heating limits the usable power; it may also apply to photostimulation and polymerisation paths.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-27
DOI
https://doi.org/10.64898/2026.11.27.769678
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Optimisation of femtosecond dispersion compensation at the sample using side-view two-photon fluorescence imaging

Małgorzata Szczerska, Jacek Łubiński, Jakub Czubek, Filip K. Janiak et al.
bioRxiv (Cold Spring Harbor Laboratory)
Advanced Fluorescence Microscopy Techniques
preprint

Optimisation of femtosecond dispersion compensation at the sample using side-view two-photon fluorescence imaging

Małgorzata Szczerska, Jacek Łubiński, Jakub Czubek, Filip K. Janiak, Grzegorz Orlicki
preprint en

Abstract

Efficient two-photon absorption depends on compensating the dispersion of the whole excitation path. Building on established fluorescence-based adjustment, we describe a practical procedure that uses side-view images of fluorescence in a dye cuvette, independently of the microscope's scanning and detection, with reference records, stability warnings and open analysis software. For a 1045 nm laser, maxima lay between 21 and 24 screw turns in 11 of 13 sweeps. For a 920 nm laser, fluorescence maxima at the sample differed by 1.63 kfs^2 on average from autocorrelation minima before the scan optics. The recordings also show limitations from signal instability and proximity to clipping. The procedure targets two-photon microscopes for in vivo imaging, such as of neuronal activity, where tissue heating limits the usable power; it may also apply to photostimulation and polymerisation paths.

bioRxiv (Cold Spring Harbor Laboratory)
University of Sussex (GB), Gdańsk University of Technology (PL)
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Optimisation of femtosecond dispersion compensation at the sample using side-view two-photon fluorescence imaging — Małgorzata Szczerska, Jacek Łubiński, et al. · bioRxiv (Cold Spring Harbor Laboratory) (2026) | TGRS Research Map | TGRS