A Harmonic Control Array (HCA) Based Motor Drive Application for a Three-Phase Three-Level I-Type NPC Inverter: A Comparative Total Harmonic Distortion Analysis
Power inverters in electric motor drives generate undesirable harmonics due to their switched structure, causing additional heating, torque ripple, and efficiency loss. The Harmonic Control Array (HCA) decomposes error signals into Fourier components, managing each harmonic independently to selectively target specific frequencies. While previously evaluated in single-phase inverters and active filters, HCA has not been applied to multilevel inverter motor drives. In this study, a three-phase three-level I-type Neutral Point Clamped (NPC) inverter was designed, and HCA was evaluated, to the best of our knowledge, for the first time in this configuration, in an induction motor drive using a closed-loop HCA layer combined with SVPWM. Algorithm performance was investigated in MATLAB/Simulink (R2024a) and on real hardware with a 1.5 kW induction motor, comparing active and passive HCA scenarios under identical loads. With HCA, the simulated current total harmonic distortion (THD) decreased from 4.74% to 2.74%, while experimental measurements dropped from 8.94% to 2.28%. Both methods yielded consistent results, successfully keeping values below the 5% limit specified by the IEEE 519-2014 standard.
Authors
- Sude Nur Camur
- Uğur Arifoğlu (ORCID: https://orcid.org/0000-0001-8082-5448)
Institutions
- Sakarya University (TR)
Publication Details
- Journal
- Electronics
- Published
- 2026-11-27
- DOI
- https://doi.org/10.3390/electronics15235568
- Primary Topic
- Multilevel Inverters and Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00