Diagnostic Accuracy of Captopril Challenge Test in Primary Aldosteronism While Taking Interfering Medications

BACKGROUND: Diagnosing primary aldosteronism requires discontinuing interfering antihypertensives, which is not always feasible. This study assessed the diagnostic accuracy of the captopril challenge test (CCT) for primary aldosteronism in patients taking these medications. METHODS: This prospective study (NCT04991961) enrolled hypertensive patients who underwent CCT both on and off interfering medications. Diagnostic accuracy was assessed using the area under the receiver operating characteristic curve, which refers to discriminating between patients with a final diagnosis of primary aldosteronism and those with essential hypertension. The reference standard combined off-medication aldosterone/renin ratio plus off-medication CCT or saline infusion test. RESULTS: A total of 341 patients completed the study (122 primary aldosteronism, 219 essential hypertension). On-medication plasma aldosterone concentration pre-CCT and post-CCT (132.0 and 94.5 pg/mL) did not differ significantly from off-medication values (141.0 pg/mL, P=0.188; 91.2 pg/mL, P=0.122). On-medication plasma renin concentration pre-CCT and post-CCT (10.7 and 17.0 μIU/mL) was higher than off-medication values (pre: 6.6 μIU/mL, P<0.001; post: 10.4 μIU/mL, P<0.001). Plasma aldosterone concentration suppression rates on-medications were slightly lower than off-medications (28.8% versus 33.5%; P=0.016). The area under the receiver operating characteristic curve for post-CCT plasma aldosterone concentration on medications was 0.83. A cutoff of 79 pg/mL yielded a sensitivity of 0.90 and a specificity of 0.55, while a 130-pg/mL cutoff yielded a specificity of 0.91 and a sensitivity of 0.54. CONCLUSIONS: Post-CCT plasma aldosterone concentration measured on interfering medications showed moderate diagnostic discrimination and may serve as a preliminary triage tool for patients unable to discontinue medications. However, the proposed cutoffs require external validation and should not replace standard off-drug confirmatory testing.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-11-27
DOI
https://doi.org/10.1161/jaha.125.043206
Citations
1
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
2.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diagnostic Accuracy of Captopril Challenge Test in Primary Aldosteronism While Taking Interfering Medications

钟海花, Jinbo Hu, Ting Luo, Shumin Yang et al.
1 citations
Journal of the American Heart Association
Hormonal Regulation and Hypertension
2.52
article

Diagnostic Accuracy of Captopril Challenge Test in Primary Aldosteronism While Taking Interfering Medications

钟海花, Jinbo Hu, Ting Luo, Shumin Yang, Qin Wan, Qifu Li, Yihong He, Li Wei, Weiyang He, Yixin Zhang, Bin Peng, Yong Xu, Xiaoyu Lee, Ying Jing, Wei Cheng, Wei Huang, Yao Zhang
article en
1 citations

Abstract

BACKGROUND: Diagnosing primary aldosteronism requires discontinuing interfering antihypertensives, which is not always feasible. This study assessed the diagnostic accuracy of the captopril challenge test (CCT) for primary aldosteronism in patients taking these medications. METHODS: This prospective study (NCT04991961) enrolled hypertensive patients who underwent CCT both on and off interfering medications. Diagnostic accuracy was assessed using the area under the receiver operating characteristic curve, which refers to discriminating between patients with a final diagnosis of primary aldosteronism and those with essential hypertension. The reference standard combined off-medication aldosterone/renin ratio plus off-medication CCT or saline infusion test. RESULTS: A total of 341 patients completed the study (122 primary aldosteronism, 219 essential hypertension). On-medication plasma aldosterone concentration pre-CCT and post-CCT (132.0 and 94.5 pg/mL) did not differ significantly from off-medication values (141.0 pg/mL, P=0.188; 91.2 pg/mL, P=0.122). On-medication plasma renin concentration pre-CCT and post-CCT (10.7 and 17.0 μIU/mL) was higher than off-medication values (pre: 6.6 μIU/mL, P<0.001; post: 10.4 μIU/mL, P<0.001). Plasma aldosterone concentration suppression rates on-medications were slightly lower than off-medications (28.8% versus 33.5%; P=0.016). The area under the receiver operating characteristic curve for post-CCT plasma aldosterone concentration on medications was 0.83. A cutoff of 79 pg/mL yielded a sensitivity of 0.90 and a specificity of 0.55, while a 130-pg/mL cutoff yielded a specificity of 0.91 and a sensitivity of 0.54. CONCLUSIONS: Post-CCT plasma aldosterone concentration measured on interfering medications showed moderate diagnostic discrimination and may serve as a preliminary triage tool for patients unable to discontinue medications. However, the proposed cutoffs require external validation and should not replace standard off-drug confirmatory testing.

Journal of the American Heart Association
Southwest Medical University (CN), The Affiliated Yongchuan Hospital of Chongqing Medical University (CN)
Openalex Percentile: Top 16%
Hormonal Regulation and Hypertension
2.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon