Lacrimal gland ultrasound in Sjögren’s disease: application of OMERACT scoring systems and scanning technique

To characterize grayscale and vascular lacrimal gland (LG) abnormalities in Sjögren’s disease (SjD), assess the diagnostic accuracy of OMERACT grayscale (GS), colour Doppler (CD), and composite GS+CD scores, compare oblique and transverse scans, and evaluate inter-reader reliability. Patients evaluated for suspected SjD underwent LG ultra-high frequency ultrasound using a 46 MHz probe. Elementary lesions were compared between SjD and sicca. LG abnormalities were graded using OMERACT GS, CD, and composite GS+CD scores. Diagnostic accuracy, scanning orientations, and inter-reader reliability were assessed. Of 86 patients, 84 had assessable LG examinations (57 SjD, 27 sicca). Hypoechoic areas and hyperechoic bands were more frequent in SjD. Very hypoechoic areas occurred exclusively in SjD and were associated with marked Doppler signal and low-resistance flow. GS and CD had comparable performance (AUC 0.837 and 0.822); CD was less sensitive than GS but more specific at the ≥1 cutoff. The composite GS+CD score had the numerically highest AUC (0.860). Compared with transverse scanning, oblique scanning reduced non-assessable glands and detected more severe GS abnormalities in SjD, resulting in higher GS diagnostic accuracy. CD findings and performance were comparable between scans. Inter-reader agreement was moderate to substantial across scores and orientations. GS and CD OMERACT scores captured relevant abnormalities with good accuracy and moderate-to-substantial reliability, supporting their application to LG ultrasonography. Oblique scanning with high-frequency probes should complement the transverse scan. Very hypoechoic areas were highly suggestive of SjD and displayed a vascular pattern resembling that previously described in lymphoproliferative lesions.

Authors

Institutions

Publication Details

Journal
Arthritis Research & Therapy
Published
2026-11-27
DOI
https://doi.org/10.1186/s13075-026-03959-8
Primary Topic
Salivary Gland Disorders and Functions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Lacrimal gland ultrasound in Sjögren’s disease: application of OMERACT scoring systems and scanning technique

Sara Galimberti, Gianmaria Governato, Gaetano La Rocca, Andrea Delle Sedie et al.
Arthritis Research & Therapy
Salivary Gland Disorders and Functions
article

Lacrimal gland ultrasound in Sjögren’s disease: application of OMERACT scoring systems and scanning technique

Sara Galimberti, Gianmaria Governato, Gaetano La Rocca, Andrea Delle Sedie, Erica Ferrini, Giovanni Fulvio, Rossana Izzetti, Marta Mosca, Chiara Baldini, Francesco Ferro, Giovanna Gabbriellini, Giuseppe Leto
article en

Abstract

To characterize grayscale and vascular lacrimal gland (LG) abnormalities in Sjögren’s disease (SjD), assess the diagnostic accuracy of OMERACT grayscale (GS), colour Doppler (CD), and composite GS+CD scores, compare oblique and transverse scans, and evaluate inter-reader reliability. Patients evaluated for suspected SjD underwent LG ultra-high frequency ultrasound using a 46 MHz probe. Elementary lesions were compared between SjD and sicca. LG abnormalities were graded using OMERACT GS, CD, and composite GS+CD scores. Diagnostic accuracy, scanning orientations, and inter-reader reliability were assessed. Of 86 patients, 84 had assessable LG examinations (57 SjD, 27 sicca). Hypoechoic areas and hyperechoic bands were more frequent in SjD. Very hypoechoic areas occurred exclusively in SjD and were associated with marked Doppler signal and low-resistance flow. GS and CD had comparable performance (AUC 0.837 and 0.822); CD was less sensitive than GS but more specific at the ≥1 cutoff. The composite GS+CD score had the numerically highest AUC (0.860). Compared with transverse scanning, oblique scanning reduced non-assessable glands and detected more severe GS abnormalities in SjD, resulting in higher GS diagnostic accuracy. CD findings and performance were comparable between scans. Inter-reader agreement was moderate to substantial across scores and orientations. GS and CD OMERACT scores captured relevant abnormalities with good accuracy and moderate-to-substantial reliability, supporting their application to LG ultrasonography. Oblique scanning with high-frequency probes should complement the transverse scan. Very hypoechoic areas were highly suggestive of SjD and displayed a vascular pattern resembling that previously described in lymphoproliferative lesions.

Arthritis Research & Therapy
University of Pisa (IT)
Salivary Gland Disorders and Functions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon