Background Herein, we aimed to evaluate the effects of different Bayesian penalized-likelihood (BPL) reconstruction penalization factors on semi-quantitative parameters in Ga-68 DOTATATE PET/CT compared with conventional ordered subsets expectation maximization (OSEM), with particular emphasis on lesion size-dependent effects. Methods A total of 102 Ga-68 DOTATATE-avid lesions from 45 prospectively enrolled patients were evaluated using BPL and OSEM algorithms on Ga-68 DOTATATE PET/CT. Images were reconstructed from identical acquisition datasets using conventional OSEM and Q.Clear with β values of 600, 800, and 1000. Lesion SUVmax, SUVmean, tumor-to-liver ratio (TLR), liver signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared across reconstruction methods. Statistical analyses accounted for within-patient clustering and multiple comparisons. A linear mixed-effects model was used to investigate the interaction between reconstruction method and lesion diameter. Results Compared with OSEM, Q.Clear β600 significantly increased lesion SUVmax (11.08 vs. 9.13; adjusted p = 0.0012), SUVmean (7.51 vs. 5.73; p = 0.0296), TLR (1.69 vs. 1.42; p = 0.0036), and CNR (7.28 vs. 3.66; p < 0.001). β800 also significantly improved lesion SUVmax, SUVmean, and CNR, whereas β1000 showed no significant improvement in these parameters compared with OSEM. Liver SNR increased with higher β values, reaching its highest mean value at β1000 (13.54 vs. 10.66 for OSEM; adjusted p < 0.01). A significant interaction was observed between reconstruction method and lesion diameter (p = 0.0039). With β600, the median SUVmax increase relative to OSEM was 27.3% for lesions < 10 mm, 15.8% for lesions 10–<20 mm, and 10.1% for lesions ≥ 20 mm. Conclusions Q.Clear reconstruction significantly affects semi-quantitative measurements in Ga-68 DOTATATE PET/CT, with effects dependent on penalization strength and lesion size. β600 provided greater lesion uptake and contrast measurements, particularly in smaller lesions, whereas higher β values improved background noise suppression. These findings emphasize the importance of balancing quantitative lesion contrast and image noise and maintaining consistent reconstruction protocols for longitudinal PET/CT assessment.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-28
DOI
https://doi.org/10.21203/rs.3.rs-11771744/v1
Primary Topic
Medical Imaging Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

The Impact of Different Reconstruction Algorithms on Quantitative Parameters and Image Quality in Ga-68 DOTATATE PET/CT Imaging

Filiz Özülker, Selin Kesim
Research Square
Medical Imaging Techniques and Applications
preprint

The Impact of Different Reconstruction Algorithms on Quantitative Parameters and Image Quality in Ga-68 DOTATATE PET/CT Imaging

Filiz Özülker, Selin Kesim
preprint en

Abstract

Background Herein, we aimed to evaluate the effects of different Bayesian penalized-likelihood (BPL) reconstruction penalization factors on semi-quantitative parameters in Ga-68 DOTATATE PET/CT compared with conventional ordered subsets expectation maximization (OSEM), with particular emphasis on lesion size-dependent effects. Methods A total of 102 Ga-68 DOTATATE-avid lesions from 45 prospectively enrolled patients were evaluated using BPL and OSEM algorithms on Ga-68 DOTATATE PET/CT. Images were reconstructed from identical acquisition datasets using conventional OSEM and Q.Clear with β values of 600, 800, and 1000. Lesion SUVmax, SUVmean, tumor-to-liver ratio (TLR), liver signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared across reconstruction methods. Statistical analyses accounted for within-patient clustering and multiple comparisons. A linear mixed-effects model was used to investigate the interaction between reconstruction method and lesion diameter. Results Compared with OSEM, Q.Clear β600 significantly increased lesion SUVmax (11.08 vs. 9.13; adjusted p = 0.0012), SUVmean (7.51 vs. 5.73; p = 0.0296), TLR (1.69 vs. 1.42; p = 0.0036), and CNR (7.28 vs. 3.66; p < 0.001). β800 also significantly improved lesion SUVmax, SUVmean, and CNR, whereas β1000 showed no significant improvement in these parameters compared with OSEM. Liver SNR increased with higher β values, reaching its highest mean value at β1000 (13.54 vs. 10.66 for OSEM; adjusted p < 0.01). A significant interaction was observed between reconstruction method and lesion diameter (p = 0.0039). With β600, the median SUVmax increase relative to OSEM was 27.3% for lesions < 10 mm, 15.8% for lesions 10–<20 mm, and 10.1% for lesions ≥ 20 mm. Conclusions Q.Clear reconstruction significantly affects semi-quantitative measurements in Ga-68 DOTATATE PET/CT, with effects dependent on penalization strength and lesion size. β600 provided greater lesion uptake and contrast measurements, particularly in smaller lesions, whereas higher β values improved background noise suppression. These findings emphasize the importance of balancing quantitative lesion contrast and image noise and maintaining consistent reconstruction protocols for longitudinal PET/CT assessment.

Research Square
Dr Lütfi Kırdar Kartal Eğitim ve Araştırma Hastanesi (TR)
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon