The Impact of Different Reconstruction Algorithms on Quantitative Parameters and Image Quality in Ga-68 DOTATATE PET/CT Imaging
Background Herein, we aimed to evaluate the effects of different Bayesian penalized-likelihood (BPL) reconstruction penalization factors on semi-quantitative parameters in Ga-68 DOTATATE PET/CT compared with conventional ordered subsets expectation maximization (OSEM), with particular emphasis on lesion size-dependent effects. Methods A total of 102 Ga-68 DOTATATE-avid lesions from 45 prospectively enrolled patients were evaluated using BPL and OSEM algorithms on Ga-68 DOTATATE PET/CT. Images were reconstructed from identical acquisition datasets using conventional OSEM and Q.Clear with β values of 600, 800, and 1000. Lesion SUVmax, SUVmean, tumor-to-liver ratio (TLR), liver signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared across reconstruction methods. Statistical analyses accounted for within-patient clustering and multiple comparisons. A linear mixed-effects model was used to investigate the interaction between reconstruction method and lesion diameter. Results Compared with OSEM, Q.Clear β600 significantly increased lesion SUVmax (11.08 vs. 9.13; adjusted p = 0.0012), SUVmean (7.51 vs. 5.73; p = 0.0296), TLR (1.69 vs. 1.42; p = 0.0036), and CNR (7.28 vs. 3.66; p < 0.001). β800 also significantly improved lesion SUVmax, SUVmean, and CNR, whereas β1000 showed no significant improvement in these parameters compared with OSEM. Liver SNR increased with higher β values, reaching its highest mean value at β1000 (13.54 vs. 10.66 for OSEM; adjusted p < 0.01). A significant interaction was observed between reconstruction method and lesion diameter (p = 0.0039). With β600, the median SUVmax increase relative to OSEM was 27.3% for lesions < 10 mm, 15.8% for lesions 10–<20 mm, and 10.1% for lesions ≥ 20 mm. Conclusions Q.Clear reconstruction significantly affects semi-quantitative measurements in Ga-68 DOTATATE PET/CT, with effects dependent on penalization strength and lesion size. β600 provided greater lesion uptake and contrast measurements, particularly in smaller lesions, whereas higher β values improved background noise suppression. These findings emphasize the importance of balancing quantitative lesion contrast and image noise and maintaining consistent reconstruction protocols for longitudinal PET/CT assessment.
Authors
- Filiz Özülker (ORCID: https://orcid.org/0000-0003-2075-1429)
- Selin Kesim (ORCID: https://orcid.org/0000-0002-6164-9781)
Institutions
- Dr Lütfi Kırdar Kartal Eğitim ve Araştırma Hastanesi (TR)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-28
- DOI
- https://doi.org/10.21203/rs.3.rs-11771744/v1
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- preprint