Consistency-QSM: Few-Step Quantitative Susceptibility Mapping with a Physics-Guided Generative Prior

Objective: To develop an efficient, physics-guided, and robust deep learning method for single-orientation quantitative susceptibility mapping (QSM) reconstruction. Methods: We developed Consistency-QSM, which combines a generative susceptibility prior with explicit physical constraints for few-step reconstruction. Consistency distillation transfers a pretrained diffusion prior into a consistency model that directly predicts restored susceptibility maps, retaining learned susceptibility structure that generalizes across acquisition conditions while reducing the number of network evaluations. Physics-guided fine-tuning on high-quality QSM data adapts the distilled prior within the reconstruction process to correct structured inversion errors, improving susceptibility accuracy. During inference, two restoration updates with shared network weights alternate with dipole data-consistency corrections based on the QSM forward model to maintain agreement with the measured field and enable robust reconstruction. Results: Experiments on numerical, in vivo, ex vivo, and clinical data, including an eight-subject 7T cohort, show that Consistency-QSM outperforms the non-generative baselines on the three principal reference-bearing cases and demonstrates robustness to noise and orientation perturbations. With two network evaluations per patch, it remains competitive with the Diffusion-QSM teacher while reducing reconstruction time from minutes to seconds. Conclusion: Consistency-QSM combines a generative susceptibility prior with explicit physical constraints, enabling generalizable and robust QSM reconstruction with few network evaluations. Significance: This work extends consistency models to volumetric QSM, enabling generalizable reconstruction in seconds and bringing few-step generative QSM closer to routine clinical and large-cohort studies.This work has been submitted to IEEE Transactions on Biomedical Engineering for possible publication. Supplementary material is included as a separate file.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24549978
Primary Topic
Advanced MRI Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Consistency-QSM: Few-Step Quantitative Susceptibility Mapping with a Physics-Guided Generative Prior

Anhong Jiang, Yu‐Xuan Ren, Chenhuan Wu, Junxin Fan
Zenodo (CERN European Organization for Nuclear Research)
Advanced MRI Techniques and Applications
preprint

Consistency-QSM: Few-Step Quantitative Susceptibility Mapping with a Physics-Guided Generative Prior

Anhong Jiang, Yu‐Xuan Ren, Chenhuan Wu, Junxin Fan
preprint en

Abstract

Objective: To develop an efficient, physics-guided, and robust deep learning method for single-orientation quantitative susceptibility mapping (QSM) reconstruction. Methods: We developed Consistency-QSM, which combines a generative susceptibility prior with explicit physical constraints for few-step reconstruction. Consistency distillation transfers a pretrained diffusion prior into a consistency model that directly predicts restored susceptibility maps, retaining learned susceptibility structure that generalizes across acquisition conditions while reducing the number of network evaluations. Physics-guided fine-tuning on high-quality QSM data adapts the distilled prior within the reconstruction process to correct structured inversion errors, improving susceptibility accuracy. During inference, two restoration updates with shared network weights alternate with dipole data-consistency corrections based on the QSM forward model to maintain agreement with the measured field and enable robust reconstruction. Results: Experiments on numerical, in vivo, ex vivo, and clinical data, including an eight-subject 7T cohort, show that Consistency-QSM outperforms the non-generative baselines on the three principal reference-bearing cases and demonstrates robustness to noise and orientation perturbations. With two network evaluations per patch, it remains competitive with the Diffusion-QSM teacher while reducing reconstruction time from minutes to seconds. Conclusion: Consistency-QSM combines a generative susceptibility prior with explicit physical constraints, enabling generalizable and robust QSM reconstruction with few network evaluations. Significance: This work extends consistency models to volumetric QSM, enabling generalizable reconstruction in seconds and bringing few-step generative QSM closer to routine clinical and large-cohort studies.This work has been submitted to IEEE Transactions on Biomedical Engineering for possible publication. Supplementary material is included as a separate file.

Zenodo (CERN European Organization for Nuclear Research)
Tianjin University (CN), Fudan University (CN), Jinshan Hospital of Fudan University (CN), Second Affiliated Hospital of Anhui Medical University (CN)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon