Which eosinophils count? Indeterminate cells, rater reproducibility and a learned classifiability filter for a whole-slide eosinophil detector in eosinophilic oesophagitis
Background. The peak eosinophil count in eosinophilic oesophagitis (EoE) adds up per-cell decisions, and one of them is contested: whether a granular cell without a visible nucleus, or a nucleated cell with too few granules, is an eosinophil. We measured how much this decision moves the precision of a whole-slide detector, how reproducible it is for one pathologist, and whether a learned filter can remove the cells the pathologist cannot classify. Methods. One gastrointestinal pathologist labelled detector candidates from public, de-identified CC0 haematoxylin–eosin biopsy scans. A design-weighted 200-crop audit included 140 crops at score ≥ 0.9; a blinded reread assessed label repeatability. The baseline-v2 classifier used 2,810 points (418 indeterminate). A separate post hoc H-paint analysis used the same point keys with 445 indeterminate labels, spanning 21 patients and 23 slides in five fixed folds. Each fold fitted PCA, the painter, scalers and classifiers only on training patients and resampled 400 training negatives. Frozen-encoder features (M0), paint features (M1) and their combination (M2) were compared using 2,000 patient bootstrap resamples. Outer-training paint features remained in-sample. The recipe was fixed before computing its scores. Results. Among the 140 high-score audit crops, 27 were indeterminate (weighted 19.6%). Precision was 0.681 when these cells counted as false, 0.848 when excluded and 0.878 when counted as true. The indeterminate call had κ 0.41 (95% CI 0.32–0.49). The post hoc baseline-v2 patient-held-out AUC was 0.713 (95% CI 0.666–0.749). In the inductive H-paint analysis, M2 AUC for indeterminate versus classifiable candidates was 0.754 (95% CI 0.720–0.782); M2 − M0 was 0.0362 (95% CI 0.0153–0.0569). For T2 (eosinophil vs not an eosinophil or dispersed granules; indeterminate cells left out), M2 AUC was 0.970 (95% CI 0.961–0.977); M2 − M0 was 0.0028 (95% CI −0.00089 to 0.0058). Conclusions. Counting rules and annotation uncertainty materially affect detector assessment. Painting’s effect on repeatability remains unestablished by the uncontrolled, optional-painting round. The patient-held-out results estimate internal, post hoc supervised component performance; they do not establish whole-slide, external, prospective or clinical performance. Related: doi:10.5281/zenodo.23484193 (detector), doi:10.5281/zenodo.24061169 (re-read round v1), doi:10.5281/zenodo.23396883 (PathRounds). File: main text.
Authors
- Daniel Ramos Pereira De Melo
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-26
- DOI
- https://doi.org/10.5281/zenodo.24572410
- Primary Topic
- AI in cancer detection
- Type
- preprint