Compression behavior of steel‐ PVA high‐strength self‐compacting concrete short column exposed to elevated temperatures
To investigate the post‐fire mechanical behavior of high‐strength self‐compacting concrete (HSSCC) short columns reinforced with steel‐polyvinyl alcohol (S‐PVA) hybrid fibers, 45 short columns were subjected to elevated‐temperature exposure followed by axial static compression tests. The results show that, at temperatures up to 400°C, the columns exhibited brittle axial‐compression failure. With increasing temperature, the residual load‐bearing capacity of all specimens first increased and then decreased, whereas the ductility coefficient initially decreased and subsequently increased. S‐PVA hybrid fibers improved post‐failure integrity and enhanced the residual load‐bearing capacity and ductility both at ambient temperature and after elevated‐temperature exposure. Within the dosage range investigated, SCC short columns containing 0.1 vol% PVA fiber and 1.4 vol% steel fiber exhibited superior post‐heating mechanical performance. Based on Chinese design‐code equations, a residual load‐bearing‐capacity calculation method for reinforced S‐PVA‐SCC short columns after elevated‐temperature exposure was developed using curve fitting and temperature reduction factors.
Authors
- Liangli Xiao (ORCID: https://orcid.org/0000-0001-6150-1747)
- Zhao Yang (ORCID: https://orcid.org/0000-0003-2176-3472)
- Chengxiang Xu
- Tao Li
- Xinlong Kong
Institutions
- Wuhan University of Science and Technology (CN)
Publication Details
- Journal
- Structural Concrete
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1002/suco.70884
- Primary Topic
- Fire effects on concrete materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00