Diagnostic Performance, Image Quality and Radiation Dose of Ultra‐Low Dose Chest CT Compared With Chest Radiography for Latent Tuberculosis Screening: Influence of Image Reconstruction Techniques

INTRODUCTION: Latent tuberculosis infection (LTBI) affects over one quarter of the global population and poses a significant risk of reactivation in immunocompromised patients. Accurate radiological assessment is essential before initiating immunosuppressive therapies. This study evaluated the diagnostic performance, image quality, and radiation dose of ultra-low-dose CT (ULDCT) compared with chest radiography (CXR) for detecting radiological features of LTBI. METHODS: In this prospective single-centre study, adults undergoing LTBI screening prior to immunosuppressive therapy underwent standard CXR and ULDCT. Subjective image quality was independently assessed by two radiologists who were blinded to the outcomes, while objective image quality assessment was performed by a single radiologist. LTBI-related findings were recorded. Statistical analyses included interobserver agreement, paired modality comparison, and radiation dose assessment. RESULTS: ) were included. The mean ± SD effective dose for ULDCT was 0.13 ± 0.02 mSv in comparison to 0.10 ± 0.07 mSv for the CXR. ULDCT detected granulomas in 12 patients (16 lesions); CXR detected none of the CT-confirmed granulomas; maximum intensity projections identified additional lesions. CXR sensitivity for granuloma detection was 0% (95% CI: 0%-26.5%) when CT was used as the reference. ULDCT also identified pulmonary nodules, mediastinal lymphadenopathy, calcified nodes, and incidental findings not visible on CXR, including features suspicious for active tuberculosis in two cases. CONCLUSION: The results indicate that ULDCT is superior to CXR for detecting calcified granulomas and other LTBI-related thoracic findings at comparable radiation doses.

Authors

Institutions

Publication Details

Journal
Journal of Medical Radiation Sciences
Published
2026-11-25
DOI
https://doi.org/10.1002/jmrs.70147
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diagnostic Performance, Image Quality and Radiation Dose of Ultra‐Low Dose Chest CT Compared With Chest Radiography for Latent Tuberculosis Screening: Influence of Image Reconstruction Techniques

Mark F. McEntee, Davida Hehir, Niamh Moore, Gráinne Murphy et al.
Journal of Medical Radiation Sciences
Radiation Dose and Imaging
article

Diagnostic Performance, Image Quality and Radiation Dose of Ultra‐Low Dose Chest CT Compared With Chest Radiography for Latent Tuberculosis Screening: Influence of Image Reconstruction Techniques

Mark F. McEntee, Davida Hehir, Niamh Moore, Gráinne Murphy, Michael Waldron, Andrew England, Eid Kakish, Ronan James Lee, Patrick W. O’Regan, Michael M. Maher, Sahil S Shet, Micheal G Murphy, Louise Beagan, Ludolf G A De Kock, Brid Normoyle
article en

Abstract

INTRODUCTION: Latent tuberculosis infection (LTBI) affects over one quarter of the global population and poses a significant risk of reactivation in immunocompromised patients. Accurate radiological assessment is essential before initiating immunosuppressive therapies. This study evaluated the diagnostic performance, image quality, and radiation dose of ultra-low-dose CT (ULDCT) compared with chest radiography (CXR) for detecting radiological features of LTBI. METHODS: In this prospective single-centre study, adults undergoing LTBI screening prior to immunosuppressive therapy underwent standard CXR and ULDCT. Subjective image quality was independently assessed by two radiologists who were blinded to the outcomes, while objective image quality assessment was performed by a single radiologist. LTBI-related findings were recorded. Statistical analyses included interobserver agreement, paired modality comparison, and radiation dose assessment. RESULTS: ) were included. The mean ± SD effective dose for ULDCT was 0.13 ± 0.02 mSv in comparison to 0.10 ± 0.07 mSv for the CXR. ULDCT detected granulomas in 12 patients (16 lesions); CXR detected none of the CT-confirmed granulomas; maximum intensity projections identified additional lesions. CXR sensitivity for granuloma detection was 0% (95% CI: 0%-26.5%) when CT was used as the reference. ULDCT also identified pulmonary nodules, mediastinal lymphadenopathy, calcified nodes, and incidental findings not visible on CXR, including features suspicious for active tuberculosis in two cases. CONCLUSION: The results indicate that ULDCT is superior to CXR for detecting calcified granulomas and other LTBI-related thoracic findings at comparable radiation doses.

Journal of Medical Radiation Sciences
University of Southern Denmark (DK), University College Cork (IE), Cork University Hospital (IE)
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.