ENHANCING THE EFFECT OF BUILDING FACADES ON THERMAL COMFORT USING ADAPTIVE DESIGN

Fully glazed façades often cause overheating and heavy air-conditioning use in hot climates. This study investigates how a simulation-driven adaptive design approach can improve thermal comfort behind an existing glazed façade, using the southwest curtain wall of the Faculty of Engineering at Damanhour University, Egypt, as a case study. The methodology combined field observation, temperature measurements and occupant interviews with parametric simulation (Rhino, Grasshopper, Ladybug, Honeybee/EnergyPlus). Three configurations of a representative office were compared: the existing façade, vertical fins, and an egg-crate system of horizontal overhangs with vertical fins. Performance was judged by annual operative temperature and the share of occupied hours within the adaptive comfort zone. Comfort hours rose from 2% in the baseline to 11% with vertical fins and 25% with the egg-crate system, which cut peak operative temperature by 6 °C. Shading geometry must match façade orientation, and the workflow is replicable for retrofitting glazed buildings in hot climates.

Authors

Institutions

Publication Details

Journal
Journal of Al-Azhar University Engineering Sector
Published
2026-11-26
DOI
https://doi.org/10.21608/auej.2026.507837.2173
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ENHANCING THE EFFECT OF BUILDING FACADES ON THERMAL COMFORT USING ADAPTIVE DESIGN

Shaimaa Fekry Abou Shousha, Razan Ibrahem Arafa
Journal of Al-Azhar University Engineering Sector
Building Energy and Comfort Optimization
article

ENHANCING THE EFFECT OF BUILDING FACADES ON THERMAL COMFORT USING ADAPTIVE DESIGN

Shaimaa Fekry Abou Shousha, Razan Ibrahem Arafa
article en

Abstract

Fully glazed façades often cause overheating and heavy air-conditioning use in hot climates. This study investigates how a simulation-driven adaptive design approach can improve thermal comfort behind an existing glazed façade, using the southwest curtain wall of the Faculty of Engineering at Damanhour University, Egypt, as a case study. The methodology combined field observation, temperature measurements and occupant interviews with parametric simulation (Rhino, Grasshopper, Ladybug, Honeybee/EnergyPlus). Three configurations of a representative office were compared: the existing façade, vertical fins, and an egg-crate system of horizontal overhangs with vertical fins. Performance was judged by annual operative temperature and the share of occupied hours within the adaptive comfort zone. Comfort hours rose from 2% in the baseline to 11% with vertical fins and 25% with the egg-crate system, which cut peak operative temperature by 6 °C. Shading geometry must match façade orientation, and the workflow is replicable for retrofitting glazed buildings in hot climates.

Journal of Al-Azhar University Engineering Sector
Damanhour University (EG)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon