Influence of pulse shape and coil orientation on TMS activation patterns using biophysical axon models

Objective. Despite the clinical prevalence of transcranial magnetic stimulation (TMS), the precise relationship between stimulation parameters and the resulting activation patterns of the axons remains elusive, particularly regarding the interaction between pulse waveforms and coil orientations. Approach. We developed a computational model that combines magnetic resonance image (MRI), white matter tractography, electric field analysis, and biophysical axon models. Using this computational framework, ten publicly available TMS pulse shapes—categorised into monophasic, half-sine, and biphasic waveforms—were evaluated across a 360° range of coil orientations. Focusing specifically on posterior-anterior (PA), anterior-posterior (AP), lateral-medial (LM), and medial-lateral (ML) directions, the model predicted activation intensities and activation sites within the hand area of the primary motor cortex (M1). Main results. Simulated activation intensity ratios matched empirical data from the literature. Excitation using monophasic AP-TMS requires higher electric field intensity compared to PA-TMS. Specifically, AP-TMS activation sites are predicted to be more distal from M1, often occurring in the postcentral gyrus or underneath the central sulcus. Axons are more likely activated under the pulse’s negative phase using half sine and biphasic waveforms. Higher threshold is required for activation at LM and ML coil orientations according to model prediction. Significance. Our computational model can be used to generate hypotheses regarding the effect of pulse waveforms and coil orientations against the measurements and observations; and it may assist users to select coil orientations and intensities of TMS for different stimulation targets.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-26
DOI
https://doi.org/10.1088/1361-6560/aec758
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of pulse shape and coil orientation on TMS activation patterns using biophysical axon models

Ilkka Laakso, Wenzhe He
Physics in Medicine and Biology
Transcranial Magnetic Stimulation Studies
article

Influence of pulse shape and coil orientation on TMS activation patterns using biophysical axon models

Ilkka Laakso, Wenzhe He
article en

Abstract

Objective. Despite the clinical prevalence of transcranial magnetic stimulation (TMS), the precise relationship between stimulation parameters and the resulting activation patterns of the axons remains elusive, particularly regarding the interaction between pulse waveforms and coil orientations. Approach. We developed a computational model that combines magnetic resonance image (MRI), white matter tractography, electric field analysis, and biophysical axon models. Using this computational framework, ten publicly available TMS pulse shapes—categorised into monophasic, half-sine, and biphasic waveforms—were evaluated across a 360° range of coil orientations. Focusing specifically on posterior-anterior (PA), anterior-posterior (AP), lateral-medial (LM), and medial-lateral (ML) directions, the model predicted activation intensities and activation sites within the hand area of the primary motor cortex (M1). Main results. Simulated activation intensity ratios matched empirical data from the literature. Excitation using monophasic AP-TMS requires higher electric field intensity compared to PA-TMS. Specifically, AP-TMS activation sites are predicted to be more distal from M1, often occurring in the postcentral gyrus or underneath the central sulcus. Axons are more likely activated under the pulse’s negative phase using half sine and biphasic waveforms. Higher threshold is required for activation at LM and ML coil orientations according to model prediction. Significance. Our computational model can be used to generate hypotheses regarding the effect of pulse waveforms and coil orientations against the measurements and observations; and it may assist users to select coil orientations and intensities of TMS for different stimulation targets.

Physics in Medicine and Biology
Aalto University (FI)
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Influence of pulse shape and coil orientation on TMS activation patterns using biophysical axon models — Ilkka Laakso, Wenzhe He · Physics in Medicine and Biology (2026) | TGRS Research Map | TGRS