Venoarterial extracorporeal membrane oxygenation provides flow, not afterload: reframing left ventricular afterload during peripheral VA ECMO
Venoarterial extracorporeal membrane oxygenation (VA ECMO) restores systemic perfusion and oxygen delivery, most commonly through peripheral femoro-femoral cannulation with retrograde arterial return into the descending aorta. From this configuration emerged the concept that peripheral VA ECMO intrinsically increases left ventricular (LV) afterload [ 1 ] because retrograde flow opposes native LV ejection. This concept has strongly influenced routine LV unloading strategies during VA ECMO [ 2 , 3 , 4 ].